2017 S CORINTH AVE 90025

Certificate Information: 2017 S CORINTH AVE 90025

Application / Permit
18014-20000-04053
Plan Check / Job No.
B18VN12167
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(2) Duplex
Work Description
48' 2" x 26' 6" IRRGULAR-SHAPED ADDITION & REMODEL SINGLE FAMILY DWELLING. ALL WORK DONE PER STRUCTURAL ENGINEERING.
Permit Issued
Issued on 1/15/2019
Issuing Office
West Los Angeles
Current Status
Issued on 1/15/2019
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 7/17/2018 APPLICANT
Assigned to Plan Check Engineer 7/18/2018 MENA WASSEF
Corrections Issued 7/19/2018 MENA WASSEF
Building Plans Picked Up 7/20/2018 APPLICANT
Applicant returned to address corrections 7/24/2018 JAHANSHAH POURHASSAN
Applicant returned to address corrections 8/31/2018 MENA WASSEF
Plan Check Approved 12/12/2018 ARTIN ZARUKIAN
Issued 1/15/2019 LADBS
CofO in Progress 8/29/2019 ROBERT SHELLY
CofO Issued-Status Void 9/5/2019 VINCENT COTTON
Permit Finaled-Status Void 9/5/2019 VINCENT COTTON
Re-Activate Permit 1/6/2020 VINCENT COTTON

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 7/23/2018 MICHAEL CASTILLO
Roof/Waste drainage to street Cleared 7/23/2018 MICHAEL CASTILLO
Sewer availability Cleared 7/23/2018 MICHAEL CASTILLO
ZA Case Cleared 7/23/2018 EDBER MACEDO
ZA Case Cleared 7/23/2018 EDBER MACEDO

Contact Information

Contractor Cirkic Asmir; Lic. No.: 996302-B 26820 PAMELA DRIVE      SANTA CLARITA, CA 91351
Engineer Guivatchian, Mohammad; Lic. No.: C36510 4720 DEGOVIA AVENUE      WOODLAND HILLS, CA 91364

Inspector Information

ANTHONY EGSON, (310) 914-3893 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 2/11/2019 Partial Approval ANTHONY MCDOWALL
BUILDING-Rough-Frame 3/13/2019 Partial Approval EVAN COOPER
Floor/Roof Diaphrgm/Shear Wall 4/16/2019 Corrections Issued EVAN COOPER
ELECTRICAL-Rough 5/3/2019 Not Ready for Inspection ROBERT SHELLY
ELECTRICAL-Rough 5/8/2019 Approved EVAN COOPER
PLUMBING-Rough 5/8/2019 Approved EVAN COOPER
HVAC-Rough 5/9/2019 Corrections Issued EVAN COOPER
Interior/Exterior Lathing 5/24/2019 Not Ready for Inspection ROBERT SHELLY
Insulation 6/4/2019 Approved EVAN COOPER
Sewer 6/5/2019 Not Ready for Inspection EVAN COOPER
Drywall Nailing 6/13/2019 Partial Approval EVAN COOPER
Green Building Rough 6/13/2019 Not Ready for Inspection EVAN COOPER
Special/Order Compliance 7/3/2019 Partial Approval ROBERT SHELLY
Special/Order Compliance 7/10/2019 Not Ready for Inspection OGANES TARAKHCHYAN
PLUMBING-Rough 7/12/2019 Partial Approval ROBERT SHELLY
BUILDING-Rough-Frame 7/19/2019 Partial Inspection ROBERT SHELLY
Drywall Nailing 7/19/2019 Approved ROBERT SHELLY
Final 7/19/2019 Not Ready for Inspection ROBERT SHELLY
Footing/Foundation/Slab 7/19/2019 Approved ROBERT SHELLY
Green Building Final 7/19/2019 Approved ROBERT SHELLY
Green Building Rough 7/19/2019 Approved ROBERT SHELLY
MERV13>=Final 7/19/2019 Not Ready for Inspection ROBERT SHELLY
MERV13>=Rough 7/19/2019 Not Ready for Inspection ROBERT SHELLY
SGSOV-Seismic Gas S/O Valve 7/19/2019 SGSOV Gas Company ROBERT SHELLY
Smoke Detectors 7/19/2019 Approved ROBERT SHELLY
BUILDING-Rough-Frame 7/23/2019 Approved ROBERT SHELLY
Final 7/23/2019 Not Ready for Inspection ROBERT SHELLY
MERV13>=Final 7/23/2019 Corrections Issued ROBERT SHELLY
MERV13>=Rough 7/23/2019 Approved ROBERT SHELLY
Final 8/22/2019 Not Ready for Inspection ROBERT SHELLY
MERV13>=Final 8/22/2019 Approved ROBERT SHELLY
Final 8/26/2019 Conditional Approval ROBERT SHELLY