8065 S KENTWOOD AVE 90045
Certificate Information: 8065 S KENTWOOD AVE 90045
- Application / Permit
- 18014-20000-02442
- Plan Check / Job No.
- B18VN07596
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSE 1ST FLOOR AND NEW 2ND FLOOR ADDITION WITH MAJOR REMODEL TO (E) ONE STORY SFD WITH (N) ATTACHED 1 CAR GARAGE AND TRELLIS _BUILDING SHALL BE FULLY SPRINKLER THROUGH OUT WITH NFPA 13D [SEE COMMENTS].
- Permit Issued
- Issued on 11/4/2022
- Issuing Office
- Valley
- Current Status
- Issued on 11/4/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 5/4/2018 | APPLICANT |
| Green Plans Picked Up | 6/8/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 6/14/2018 | DAWN MC NULTY |
| Corrections Issued | 6/22/2018 | DAWN MC NULTY |
| Quality Review Completed | 6/25/2018 | CHON CHIO KUO |
| Building Plans Picked Up | 6/27/2018 | APPLICANT |
| Applicant returned to address corrections | 1/10/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 1/31/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 3/14/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 4/9/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 10/9/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 11/5/2019 | DAWN MC NULTY |
| Applicant returned to address corrections | 2/11/2020 | DAWN MC NULTY |
| Applicant returned to address corrections | 3/22/2021 | DAWN MC NULTY |
| Plan Check Approved | 7/18/2022 | DAWN MC NULTY |
| Issued | 11/4/2022 | APPLICANT |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 5/10/2019 | GUILLERMO PETRA |
| Permit | Cleared | 5/10/2019 | GUILLERMO PETRA |
| Sewer availability | Cleared | 5/10/2019 | GUILLERMO PETRA |
| CPC | Cleared | 10/9/2019 | HERMINIGILDO AGUSTIN |
| CPC | Cleared | 10/9/2019 | HERMINIGILDO AGUSTIN |
| CPC | Cleared | 10/9/2019 | HERMINIGILDO AGUSTIN |
| Low Impact Development | Cleared | 10/9/2019 | ORVAL HERNANDEZ-MARCIAL |
| Roof/Waste drainage to street | Cleared | 10/9/2019 | GUILLERMO PETRA |
| Green Code | Cleared | 10/29/2019 | PARISA ZAHABI |
| Public Works-Highway Ded. | Cleared | 4/22/2026 | CHRISTINE REUSCH |
| Public Works-Open Permits | Cleared | 4/22/2026 | CHRISTINE REUSCH |
| Public Works-Sewers | Cleared | 4/22/2026 | CHRISTINE REUSCH |
Contact Information
| Architect | Lopez,, Craig Joseph; Lic. No.: C14263 | 155 GRANADA ST STE "L" CAMARILLO, CA 93010 |
| Contractor | Owner-Builder | , |
| Engineer | Su,, Yu-Ting; Lic. No.: C76714 | 28 SAGE LAKE FOREST, CA 92630 |
Inspector Information
| MORRIS JACKSON, (310) 914-3885 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Special/Order Compliance | 4/17/2024 | Corrections Issued | RICHARD STEINBACH |
| Pre-Inspection | 6/10/2024 | Partial Inspection | TEMISTOCLES CAAL |
| Excavation/Setback/Form/Re-Bar | 10/2/2024 | Partial Approval | TEMISTOCLES CAAL |
| Footing/Foundation/Slab | 10/2/2024 | Partial Approval | TEMISTOCLES CAAL |
| Footing/Foundation/Slab | 10/11/2024 | Partial Approval | TEMISTOCLES CAAL |
| Excavation/Setback/Form/Re-Bar | 10/17/2024 | Approved | TEMISTOCLES CAAL |
| Footing/Foundation/Slab | 10/17/2024 | Approved | TEMISTOCLES CAAL |
| Floor/Roof Diaphrgm/Shear Wall | 1/27/2025 | Partial Approval | MICHAEL ALLEN |
| BUILDING-Rough-Frame | 5/22/2025 | Corrections Issued | RUBEN RIVAS |
| ELECTRICAL-Rough | 5/22/2025 | Corrections Issued | RUBEN RIVAS |
| Green Building Rough | 5/22/2025 | Not Ready for Inspection | RUBEN RIVAS |
| PLUMBING-Rough | 5/22/2025 | Corrections Issued | RUBEN RIVAS |
| Wood Frame | 5/22/2025 | Not Ready for Inspection | RUBEN RIVAS |
| BUILDING-Rough-Frame | 7/15/2025 | Corrections Issued | RUBEN RIVAS |
| ELECTRICAL-Rough | 7/15/2025 | Corrections Issued | RUBEN RIVAS |
| Green Building Rough | 7/15/2025 | Not Ready for Inspection | RUBEN RIVAS |
| Rough-Elec/Plmb/HVAC | 7/15/2025 | Partial Approval | RUBEN RIVAS |
| BUILDING-Rough-Frame | 7/18/2025 | Corrections Issued | RUBEN RIVAS |
| Green Building Rough | 7/18/2025 | Not Ready for Inspection | RUBEN RIVAS |
| BUILDING-Rough-Frame | 7/28/2025 | Partial Approval | RUBEN RIVAS |
| Green Building Rough | 7/28/2025 | Not Ready for Inspection | RUBEN RIVAS |
| Interior/Exterior Lathing | 8/19/2025 | Partial Approval | TEMISTOCLES CAAL |
| Special/Order Compliance | 8/19/2025 | Partial Inspection | BOBBY KEY |
| Special/Order Compliance | 8/19/2025 | Partial Inspection | HERBERT GIRON |
| Special/Order Compliance | 8/19/2025 | Partial Inspection | JAYLIN GRAVITTE |
| Insulation | 8/21/2025 | Corrections Issued | RUBEN RIVAS |
| Insulation | 8/29/2025 | Approved | RUBEN RIVAS |
| Drywall Nailing | 9/2/2025 | Approved | RUBEN RIVAS |
| Special/Order Compliance | 3/2/2026 | Not Ready for Inspection | ANTHONY EGSON |
| Special/Order Compliance | 3/5/2026 | Corrections Issued | ANTHONY EGSON |
| Special/Order Compliance | 3/6/2026 | Approved | ANTHONY EGSON |
| ELECTRICAL-Final | 4/1/2026 | Partial Inspection | ANTHONY EGSON |
| ELECTRICAL-Final | 4/23/2026 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Final | 5/4/2026 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Final | 5/8/2026 | Approved | ANTHONY EGSON |
| HVAC-Final | 5/8/2026 | Corrections Issued | ANTHONY EGSON |
| PLUMBING-Final | 5/8/2026 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Final | 5/19/2026 | Approved | MORRIS JACKSON |
| HVAC-Final | 5/19/2026 | Approved | MORRIS JACKSON |
| PLUMBING-Final | 5/19/2026 | Approved | MORRIS JACKSON |
| ELECTRICAL-Final | 6/22/2026 | Approved | MORRIS JACKSON |
| Service/Power Release | 6/22/2026 | Approved | MORRIS JACKSON |