980 N STONE CANYON ROAD 90077

Certificate Information: 980 N STONE CANYON ROAD 90077

Application / Permit
18010-30001-03708
Plan Check / Job No.
B20WL02717
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
supplemental ref to pcis # 18010-30000-03708, to convert proposed cabana to ADU w/ (n) additions per state law. (See comment)
Permit Issued
Issued on 3/15/2021
Issuing Office
Current Status
Permit Finaled on 4/17/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/26/2020 APPLICANT
Assigned to Plan Check Engineer 7/23/2020 KAMRAN GHOTBI RAVANDI
Corrections Issued 7/27/2020 KAMRAN GHOTBI RAVANDI
Quality Review Completed 7/28/2020 CHIHARU SUZUKI
Building Plans Picked Up 7/30/2020 APPLICANT
Plan Check Approved 3/2/2021 KAMRAN GHOTBI RAVANDI
Issued 3/15/2021 APPLICANT
Permit Finaled 4/17/2024 CHRISTOPHER WILSON

Permit Application Clearance Information

BHO/Hillside ordinance Cleared 10/2/2020 HISASHI KOBAYAKAWA
BHO/Hillside ordinance Cleared 10/2/2020 HISASHI KOBAYAKAWA
BHO/Hillside ordinance Cleared 10/2/2020 HISASHI KOBAYAKAWA
Watercourse Cleared 10/2/2020 HISASHI KOBAYAKAWA
Eng Process Fee Ord 176,300 Cleared 10/6/2020 HISASHI KOBAYAKAWA
Sewer availability Cleared 10/6/2020 HISASHI KOBAYAKAWA
ZA Case Cleared 10/6/2020 DENZEL HENDERSON
ZI Cleared 10/6/2020 DENZEL HENDERSON
Address approval Cleared 10/9/2020 HISASHI KOBAYAKAWA
Flood clearance Cleared 12/1/2020 RAYMOND LAM
Low Impact Development Cleared 12/3/2020 MARTIN FRAGOSO
Hydrant and Access approval Cleared 12/15/2020 MATTHEW CRAIG
Roof/Waste drainage to street Cleared 1/13/2021 HISASHI KOBAYAKAWA

Contact Information

Contractor Silverston & Associates Inc; Lic. No.: 488695-B 3480 LOS FLORES CYN      MALIBU, CA 90265
Engineer Erdelyi, Peter Tibor; Lic. No.: C26962 1950 SAWTELLE BLVD STE 175      LOS ANGELES, CA 90025
Engineer Masterman, Gary Clyde; Lic. No.: GE567 4580 MOHAWK DR      LARKSPUR, CO 80118
Geologist Schick, John Wayne; Lic. No.: EG1300 7650 HASKELL AVENUE STE D      VAN NUYS, CA 91406

Inspector Information

RYAN SALAZAR, (310) 914-3862 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 3/23/2021 Not Ready for Inspection CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 4/21/2021 Corrections Issued CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 5/6/2021 Partial Approval CHRISTOPHER WILSON
Piling/Pier/Caisson 5/6/2021 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 7/23/2021 Not Ready for Inspection CHRISTOPHER WILSON
Footing/Foundation/Slab 7/23/2021 Not Ready for Inspection CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 7/29/2021 Not Ready for Inspection CHRISTOPHER WILSON
Deputy Reinf. Concrete 7/30/2021 Conditional Approval DANIEL ORRANTE
Excavation/Setback/Form/Re-Bar 8/2/2021 Corrections Issued CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 8/4/2021 Approved CHRISTOPHER WILSON
Pre-Inspection 8/4/2021 Partial Approval CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 1/27/2022 Corrections Issued CHRISTOPHER WILSON
FLOOD-Proofing Certificate 2/18/2022 Not Ready for Inspection CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 2/18/2022 Partial Approval CHRISTOPHER WILSON
Verify Sprinkler Sign Off 2/18/2022 Not Ready for Inspection CHRISTOPHER WILSON
Interior/Exterior Lathing 5/31/2022 Corrections Issued CHRISTOPHER WILSON
FLOOD-Proofing Certificate 6/17/2022 Not Ready for Inspection CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 6/17/2022 Approved CHRISTOPHER WILSON
Interior/Exterior Lathing 6/17/2022 Not Ready for Inspection CHRISTOPHER WILSON
Verify Sprinkler Sign Off 6/17/2022 Approved CHRISTOPHER WILSON
Wood Frame 6/17/2022 Not Ready for Inspection CHRISTOPHER WILSON
Pre-Inspection 6/22/2022 Partial Approval CHRISTOPHER WILSON
FLOOD-Proofing Certificate 6/29/2022 Approved CHRISTOPHER WILSON
Interior/Exterior Lathing 6/29/2022 Partial Approval CHRISTOPHER WILSON
Wood Frame 6/29/2022 Approved CHRISTOPHER WILSON
Insulation 7/20/2022 Approved CHRISTOPHER WILSON
Drywall Nailing 7/26/2022 Approved CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 8/3/2022 Corrections Issued CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 8/5/2022 Not Ready for Inspection CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 8/9/2022 Partial Approval CHRISTOPHER WILSON
Special/Order Compliance 3/30/2024 Corrections Issued CHRISTOPHER WILSON
Final 4/9/2024 Corrections Issued CHRISTOPHER WILSON
Pre-Inspection 4/10/2024 Partial Approval CHRISTOPHER WILSON
Final 4/15/2024 Conditional Approval CHRISTOPHER WILSON
Smoke Detectors 4/15/2024 Approved CHRISTOPHER WILSON
Special/Order Compliance 4/16/2024 Partial Inspection CHRISTOPHER WILSON