5330 1/2 N AGNES AVE 91607

Certificate Information: 5330 1/2 N AGNES AVE 91607

Application / Permit
18010-30000-00773
Plan Check / Job No.
B18WL01190
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PARCEL D: NEW 3-STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE PER SMALL LOT SUBDIVISION PER AA-2017-2322-PMLA-SL. A CERTIFICATE OF OCCUPANCY (TEMPORARY OR FINAL) SHALL NOT BE ISSUED UNTIL AFTER THE FINAL MAP HAS BEEN RECORDED.
Permit Issued
Issued on 1/15/2019
Issuing Office
West Los Angeles
Current Status
CofO Issued on 7/17/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/22/2018 APPLICANT
Assigned to Plan Check Engineer 3/15/2018 ERWIN PASCUA
Corrections Issued 4/4/2018 ERWIN PASCUA
Building Plans Picked Up 4/4/2018 APPLICANT
Quality Review Completed 4/12/2018 JOSE RODRIGUEZ
Green Plans Picked Up 9/24/2018 APPLICANT
Applicant returned to address corrections 9/27/2018 ERWIN PASCUA
Applicant returned to address corrections 10/3/2018 ERWIN PASCUA
Applicant returned to address corrections 11/13/2018 ERWIN PASCUA
Plan Check Approved 1/15/2019 ERWIN PASCUA
Issued 1/15/2019 LADBS
CofO in Progress 5/13/2021 CHARLES POWELL
Permit Finaled 7/17/2021 MICHAEL SMITH
CofO Issued 7/17/2021 MICHAEL SMITH
Permit Finaled 7/17/2021 MICHAEL SMITH

Permit Application Clearance Information

Address approval Cleared 9/19/2018 STEVE MELGAR
Hydrant and Access approval Cleared 9/20/2018 JOHN CONNEALLY
Low Impact Development Cleared 9/28/2018 ANDRES COVARRUBIAS
Eng Process Fee Ord 176,300 Cleared 10/5/2018 ADRIAN SANCHEZ
Sewer availability Cleared 10/5/2018 ADRIAN SANCHEZ
Miscellaneous Cleared 10/10/2018 RICK TORRES
Specific Plan Cleared 10/10/2018 RICK TORRES
Tract Map conditions Cleared 10/10/2018 RICK TORRES
Roof/Waste drainage to street Cleared 10/15/2018 KARAN PATEL
Green Code Cleared 10/23/2018 RICHARD GARCIA
Permit Cleared 10/31/2018 MICHAEL CASTILLO
Miscellaneous Cleared 12/12/2018 MARKOS PEREZ-BRAN
Construction near power lines Cleared 1/8/2019 WALTER RAMIREZ

Contact Information

Architect Rezvani, Farbod; Lic. No.: C32315 2007 COLDWATER CYN      BEVERLY HILLS, CA 90210
Contractor Di Nalli Construction; Lic. No.: 942979-B 9724 CRESTA DR      LOS ANGELES, CA 90035
Engineer , ; Lic. No.: C83413 22287 MULHOLLAND HWY 163      CALABASAS, CA 91302
Landscape Architect Mc, Eowen, Susan E; Lic. No.: LA2180 19197 GOLDEN VALLEY RD 924      SANTA CLARITA, CA 91387

Inspector Information

JAVIER RAMOS JR, (818) 374-1163 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 1/23/2019 Partial Approval JEFFREY PARD
Footing/Foundation/Slab 1/23/2019 Partial Approval JEFFREY PARD
PLUMBING-Rough 1/25/2019 Partial Approval JEFFREY PARD
Footing/Foundation/Slab 2/13/2019 Partial Approval JEFFREY PARD
Footing/Foundation/Slab 2/20/2019 Partial Approval JEFFREY PARD
Wood Frame 3/1/2019 Not Ready for Inspection JEFFREY PARD
Floor/Roof Diaphrgm/Shear Wall 3/4/2019 Partial Approval JEFFREY PARD
Interior/Exterior Lathing 3/15/2019 Partial Approval JEFFREY PARD
Interior/Exterior Lathing 3/22/2019 Partial Approval JEFFREY PARD
Wood Frame 4/8/2019 Partial Approval JEFFREY PARD
BUILDING-Rough-Frame 4/15/2019 Partial Approval JEFFREY PARD
Green Building Rough 4/15/2019 Not Ready for Inspection JEFFREY PARD
Verify Sprinkler Sign Off 4/15/2019 Not Ready for Inspection JEFFREY PARD
Wood Frame 4/17/2019 Partial Approval JEFFREY PARD
Floor/Roof Diaphrgm/Shear Wall 4/29/2019 Not Ready for Inspection JEFFREY PARD
Wood Frame 4/30/2019 Partial Approval JEFFREY PARD
Wood Frame 5/6/2019 Not Ready for Inspection JEFFREY PARD
Wood Frame 5/9/2019 Approved MATTHEW NELSON
Interior/Exterior Lathing 5/15/2019 Not Ready for Inspection JOHN HAYES
Wood Frame 5/22/2019 Partial Approval JEFFREY PARD
Floor/Roof Diaphrgm/Shear Wall 6/12/2019 Partial Approval JEFFREY PARD
Wood Frame 6/19/2019 Partial Approval JEFFREY PARD
Interior/Exterior Lathing 6/21/2019 Not Ready for Inspection JEFFREY PARD
ELECTRICAL-Rough 6/24/2019 Approved JEFFREY PARD
HVAC-Rough 6/24/2019 Approved JEFFREY PARD
Interior/Exterior Lathing 6/24/2019 Approved JEFFREY PARD
PLUMBING-Rough 6/24/2019 Approved JEFFREY PARD
Wood Frame 6/28/2019 Not Ready for Inspection JEFFREY PARD
BUILDING-Rough-Frame 7/8/2019 Not Ready for Inspection JEFFREY PARD
Green Building Rough 7/8/2019 Not Ready for Inspection JEFFREY PARD
Verify Sprinkler Sign Off 7/8/2019 Not Ready for Inspection JEFFREY PARD
BUILDING-Rough-Frame 7/11/2019 Approved JEFFREY PARD
Green Building Rough 7/11/2019 Approved JEFFREY PARD
Verify Sprinkler Sign Off 7/11/2019 Approved JEFFREY PARD
Insulation 7/15/2019 Approved DANIEL ORRANTE
Drywall Nailing 7/19/2019 Approved JEFFREY PARD
Interior/Exterior Lathing 8/6/2019 Approved JEFFREY PARD
Shower Pan 8/6/2019 Approved JEFFREY PARD
ELECTRICAL-Final 10/16/2019 Not Ready for Inspection JEFFREY PARD
HVAC-Final 10/16/2019 Approved JEFFREY PARD
Service/Power Release 10/16/2019 Not Ready for Inspection JEFFREY PARD
ELECTRICAL-Final 10/28/2019 Not Ready for Inspection OGANES TARAKHCHYAN
ELECTRICAL-Final 11/5/2019 Approved JEFFREY PARD
PLUMBING-Final 11/6/2019 Approved JEFFREY PARD
Service/Power Release 5/14/2020 Not Ready for Inspection JEFFREY PARD
Service/Power Release 5/18/2020 Not Ready for Inspection JEFFREY PARD
Service/Power Release 5/26/2020 Approved JEFFREY PARD
Footing/Foundation/Slab 4/15/2021 Approved THOMAS FINNILA
Green Building Final 4/15/2021 Corrections Issued THOMAS FINNILA
Final 5/12/2021 OK to Issue CofO CHARLES POWELL
Green Building Final 5/12/2021 Approved CHARLES POWELL
SGSOV-Seismic Gas S/O Valve 5/12/2021 SGSOV Approved CHARLES POWELL
Smoke Detectors 5/12/2021 Approved CHARLES POWELL