12039 N ESTRELLA PL 91326
Certificate Information: 12039 N ESTRELLA PL 91326
- Application / Permit
- 18010-20000-02400
- Plan Check / Job No.
- B18VN08647
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSE TWO STORY SFD WITH ATTACHED GARAGE_BUILDING SHALL BE FULLY SPRINKLER THROUGH OUT WITH NFPA 13D (PER STANDARD PLAN # 650_PLAN 1A)
- Permit Issued
- Issued on 8/9/2018
- Issuing Office
- Valley
- Current Status
- CofO Corrected on 10/18/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/23/2018 | APPLICANT |
| Green Plans Picked Up | 6/12/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 6/14/2018 | DAWN MC NULTY |
| Corrections Issued | 6/18/2018 | DAWN MC NULTY |
| Quality Review Completed | 6/18/2018 | CHON CHIO KUO |
| Building Plans Picked Up | 6/19/2018 | APPLICANT |
| Plan Check Approved | 8/9/2018 | DAWN MC NULTY |
| Issued | 8/9/2018 | LADBS |
| CofO in Progress | 6/25/2019 | BRUCE ROZAK |
| CofO Issued-Status Void | 7/1/2019 | DONALD SUNSERI |
| Permit Finaled-Status Void | 7/1/2019 | DONALD SUNSERI |
| Re-Activate Permit | 10/16/2019 | MICHAEL SMITH |
| Permit Finaled | 10/18/2021 | MICHAEL SMITH |
| CofO Corrected | 10/18/2021 | MICHAEL SMITH |
| Permit Finaled | 10/18/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Miscellaneous | Cleared | 6/27/2018 | STEVEN WECHSLER |
| Low Impact Development | Cleared | 7/3/2018 | AMMAR ELTAWIL |
| "T" removal | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Address approval | Cleared | 7/12/2018 | HOWARD COOPER |
| BHO/Hillside ordinance | Cleared | 7/12/2018 | JOHN LIN |
| BHO/Hillside ordinance | Cleared | 7/12/2018 | JOHN LIN |
| BHO/Hillside ordinance | Cleared | 7/12/2018 | JOHN LIN |
| CPC | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Eng Process Fee Ord 176,300 | Cleared | 7/12/2018 | JOHN LIN |
| Miscellaneous | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Miscellaneous | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Permit | Cleared | 7/12/2018 | JOHN LIN |
| Roof/Waste drainage to street | Cleared | 7/12/2018 | JOHN LIN |
| Sewer availability | Cleared | 7/12/2018 | JOHN LIN |
| Specific Plan | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Tract Map conditions | Cleared | 7/12/2018 | STEVEN WECHSLER |
| ZA Case | Cleared | 7/12/2018 | STEVEN WECHSLER |
| Hydrant and Access approval | Cleared | 7/30/2018 | ROBERT DUFF |
| Green Code | Cleared | 8/9/2018 | MICHAEL AYERS |
Contact Information
| Architect | Falese, Debra Suzanne; Lic. No.: C24900 | 2943 PULLMAN SUITE A SANTA ANA, CA 92705 |
| Engineer | Miller, Karen Lynn; Lic. No.: GE2257 | 5364 DORIS WY TORRANCE, CA 90505 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 12/28/2018 | Approved | DONALD SUNSERI |
| Footing/Foundation/Slab | 1/22/2019 | Approved | BRUCE ROZAK |
| Deputy Pre-Stress Concrete | 1/23/2019 | No Access for Inspection | BRUCE ROZAK |
| Floor/Roof Diaphrgm/Shear Wall | 2/4/2019 | Partial Approval | BRUCE ROZAK |
| Sewer | 2/22/2019 | Approved | BRUCE ROZAK |
| Floor/Roof Diaphrgm/Shear Wall | 2/26/2019 | Partial Approval | BRUCE ROZAK |
| ELECTRICAL-Rough | 3/11/2019 | Approved | BRUCE ROZAK |
| HVAC-Rough | 3/11/2019 | Approved | BRUCE ROZAK |
| Deputy Wood Construction | 3/18/2019 | Approved | BRUCE ROZAK |
| PLUMBING-Rough | 3/20/2019 | Approved | BRUCE ROZAK |
| Floor/Roof Diaphrgm/Shear Wall | 3/21/2019 | Approved | BRUCE ROZAK |
| BUILDING-Rough-Frame | 3/29/2019 | Approved | DONALD SUNSERI |
| Green Building Rough | 3/29/2019 | Approved | DONALD SUNSERI |
| Verify Sprinkler Sign Off | 3/29/2019 | Approved | DONALD SUNSERI |
| Drywall Nailing | 4/3/2019 | Approved | DONALD SUNSERI |
| Interior/Exterior Lathing | 4/3/2019 | Approved | DONALD SUNSERI |
| Gas Test | 5/2/2019 | Approved | BRUCE ROZAK |
| SGSOV-Seismic Gas S/O Valve | 5/10/2019 | SGSOV Approved | BRUCE ROZAK |
| Service/Power Release | 5/23/2019 | Approved | BRUCE ROZAK |
| ELECTRICAL-Final | 6/19/2019 | Approved | DONALD SUNSERI |
| Final | 6/19/2019 | Not Ready for Inspection | DONALD SUNSERI |
| Green Building Final | 6/19/2019 | Approved | DONALD SUNSERI |
| HVAC-Final | 6/19/2019 | Approved | DONALD SUNSERI |
| PLUMBING-Final | 6/19/2019 | Approved | DONALD SUNSERI |
| Smoke Detectors | 6/19/2019 | Approved | DONALD SUNSERI |
| Final | 6/24/2019 | OK to Issue CofO | BRUCE ROZAK |
| Special/Order Compliance | 10/19/2021 | Approved | MICHAEL SMITH |