11106 W CALIFA ST 91601

Certificate Information: 11106 W CALIFA ST 91601

Application / Permit
18010-20000-00419
Plan Check / Job No.
B18VN01916
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
(N) 20'X25' DETACHED ACCESSORY DWELLING UNITS PER AB494 AND SB229. ALL WORK PER WFPP. "COMPLY WITH DEPARTMENT ORDER effective date 11/23/2017. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE"
Permit Issued
Issued on 6/20/2018
Issuing Office
Valley
Current Status
Issued on 6/20/2018
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 2/2/2018 APPLICANT
Assigned to Plan Check Engineer 2/15/2018 MARVEL DELACRUZ
Green Plans Picked Up 2/16/2018 APPLICANT
Corrections Issued 2/18/2018 MARVEL DELACRUZ
Quality Review Completed 2/21/2018 DOUGLAS NAKATANI
Building Plans Picked Up 2/23/2018 APPLICANT
Plan Check Approved 6/8/2018 MARVEL DELACRUZ
Issued 6/20/2018 LADBS

Permit Application Clearance Information

Address approval Cleared 3/14/2018 STEVE MELGAR
Eng Process Fee Ord 176,300 Cleared 3/14/2018 STEVE MELGAR
Sewer availability Cleared 3/14/2018 STEVE MELGAR
Low Impact Development Cleared 3/28/2018 MITESH PATEL
Roof/Waste drainage to street Cleared 3/28/2018 ADRIAN SANCHEZ
Green Code Cleared 4/3/2018 SARKIS HARABEDIAN
Construction near power lines Cleared 5/25/2018 RIDWAN HARDY

Contact Information

Engineer Chaaya, Danny Camille; Lic. No.: C45555 P O BOX 46341      LOS ANGELES, CA 90046

Inspector Information

GAREN HAYRAPETYAN, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI
ROBERTO PALACIOS-LOPEZ, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/3/2018 Partial Approval KEVIN BEAULIEU
PLUMBING-Rough 7/3/2018 Partial Approval KEVIN BEAULIEU
Excavation/Setback/Form/Re-Bar 7/11/2018 Approved KEVIN BEAULIEU
ELECTRICAL-Rough 7/30/2018 No Access for Inspection RUBEN REYES
Green Building Rough 7/30/2018 No Access for Inspection RUBEN REYES
PLUMBING-Rough 7/30/2018 No Access for Inspection RUBEN REYES
Verify Sprinkler Sign Off 7/30/2018 No Access for Inspection RUBEN REYES
BUILDING-Rough-Frame 7/31/2018 Partial Approval KEVIN BEAULIEU
Insulation 8/20/2018 Not Ready for Inspection KEVIN BEAULIEU
HVAC-Rough 8/28/2018 Approved KEVIN BEAULIEU
Drywall Nailing 9/10/2018 Not Ready for Inspection KEVIN BEAULIEU
Interior/Exterior Lathing 9/10/2018 Not Ready for Inspection KEVIN BEAULIEU
Shower Pan 9/10/2018 Approved KEVIN BEAULIEU
Floor/Roof Diaphrgm/Shear Wall 10/11/2018 Approved JEFFREY PARD
Interior/Exterior Lathing 10/11/2018 Partial Approval JEFFREY PARD
Pre-Inspection 10/11/2018 Approved JEFFREY PARD
Wood Frame 10/11/2018 Approved JEFFREY PARD
BUILDING-Rough-Frame 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Drywall Nailing 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Final 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Footing/Foundation/Slab 11/6/2018 Approved KEVIN BEAULIEU
Green Building Final 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Green Building Rough 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
SGSOV-Seismic Gas S/O Valve 11/6/2018 SGSOV Not Ready KEVIN BEAULIEU
Service/Power Release 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Smoke Detectors 11/6/2018 Not Ready for Inspection KEVIN BEAULIEU
Verify Sprinkler Sign Off 11/6/2018 Approved KEVIN BEAULIEU
BUILDING-Rough-Frame 12/18/2018 Approved GREG ALLTON
Drywall Nailing 12/18/2018 Approved GREG ALLTON
Final 12/18/2018 Not Ready for Inspection GREG ALLTON
Green Building Final 12/18/2018 Approved GREG ALLTON
Green Building Rough 12/18/2018 Approved GREG ALLTON
SGSOV-Seismic Gas S/O Valve 12/18/2018 SGSOV Approved GREG ALLTON
Service/Power Release 12/18/2018 Not Ready for Inspection GREG ALLTON
Smoke Detectors 12/18/2018 Approved GREG ALLTON
Final 12/24/2018 Not Ready for Inspection KEVIN BEAULIEU
Service/Power Release 12/24/2018 Not Ready for Inspection KEVIN BEAULIEU