1537 S WILTON PL 1-22 90019
Certificate Information: 1537 S WILTON PL 1-22 90019
- Application / Permit
- 18010-10004-03493
- Plan Check / Job No.
- B22LA14007
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SUPPLEMENTAL PERMIT TO 18010-10000-03493. EXISITING GYM TO BE CONVERTED INTO ADU. EXISITING STUDIO UNIT TO BE CONVERTED TO 1 BEDROOM UNIT AND REVISE STRUCTURAL PLAN.
- Permit Issued
- Issued on 12/14/2022
- Issuing Office
- Metro
- Current Status
- Permit Finaled on 4/6/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 7/18/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 7/28/2022 | ERIC WONG |
| Corrections Issued | 7/30/2022 | ERIC WONG |
| Quality Review Completed | 8/5/2022 | PETER KIM |
| Green Plans Picked Up | 8/8/2022 | APPLICANT |
| Building Plans Picked Up | 8/12/2022 | APPLICANT |
| Disabled Access Plans Picked Up | 9/8/2022 | APPLICANT |
| Applicant returned to address corrections | 9/30/2022 | ERIC WONG |
| Plan Check Approved | 12/2/2022 | ERIC WONG |
| Issued | 12/14/2022 | APPLICANT |
| Permit Finaled | 4/3/2026 | JOEY BUCHANAN |
Permit Application Clearance Information
| Address approval | Cleared | 9/8/2022 | CINDY QI |
| Eng Process Fee Ord 176,300 | Cleared | 9/12/2022 | CINDY QI |
| Sewer availability | Cleared | 9/12/2022 | CINDY QI |
| Miscellaneous | Cleared | 9/13/2022 | KENTON TRINH |
| Green Code | Cleared | 9/29/2022 | AARON COSTA |
| Fire Marshal Fire Life Safety | Cleared | 10/28/2022 | DOMINIQUE MEDINA |
| DAS Clearance | Cleared | 11/17/2022 | ELIZABETH TOMS |
Contact Information
| Architect | Ko,, Michael Myungsoo; Lic. No.: C22356 | 3435 WILSHIRE BLVD #2905 LOS ANGELES, CA 90010 |
| Contractor | Fei Enterprises Inc; Lic. No.: 659252-B | 5967 W 3RD ST 100 LOS ANGELES, CA 90036 |
| Engineer | Hill,, Edward Foster; Lic. No.: GE2126 | 27865 AMBERWOOD LANE VALENCIA, CA 91354 |
| Engineer | Tuchscher,, James Todd; Lic. No.: C77649 | 5503 E 2ND ST LONG BEACH, CA 90803 |
Inspector Information
| NICK DANERI, (213) 202-5615 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 2/21/2023 | Partial Approval | JAMES POWERS |
| Insulation | 11/29/2023 | Partial Inspection | NICK DANERI |
| Wood Frame | 11/29/2023 | Conditional Approval | NICK DANERI |
| Final | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| Green Building Final | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| Green Building Rough | 1/6/2025 | Approved | NICK DANERI |
| METHANE-Final | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| METHANE-Rough | 1/6/2025 | Approved | NICK DANERI |
| Reinforced Concrete Frame | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| Reinforced Masonry Frame | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| Smoke Detectors | 1/6/2025 | Not Ready for Inspection | NICK DANERI |
| Final | 4/3/2026 | Permit Finaled | JOEY BUCHANAN |
| Green Building Final | 4/3/2026 | Approved | JOEY BUCHANAN |
| METHANE-Final | 4/3/2026 | Approved | JOEY BUCHANAN |
| METHANE-Rough | 4/3/2026 | Approved | JOEY BUCHANAN |
| Reinforced Concrete Frame | 4/3/2026 | Approved | JOEY BUCHANAN |
| Reinforced Masonry Frame | 4/3/2026 | Approved | JOEY BUCHANAN |
| Smoke Detectors | 4/3/2026 | Approved | JOEY BUCHANAN |