462-462 1/2 N CRANE BLVD 90065

Certificate Information: 462-462 1/2 N CRANE BLVD 90065

Application / Permit
18010-10001-04703
Plan Check / Job No.
B23LA18825
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Supplemental to permit #18010-10000-04703 to convert attached 2 car garage to attached Accessory Dwelling Unit per State Law CA Govt. Code 65852.2(e)(1)(A). and removal of parking requirements per AB 2097.
Permit Issued
Issued on 4/10/2024
Issuing Office
Metro
Current Status
Permit Finaled on 10/8/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/6/2023 APPLICANT
Assigned to Plan Check Engineer 10/11/2023 GARO TELMI
Corrections Issued 10/26/2023 GARO TELMI
Quality Review Completed 10/27/2023 KEN GILL
Building Plans Picked Up 10/30/2023 APPLICANT
Applicant returned to address corrections 3/20/2024 GARO TELMI
Applicant returned to address corrections 4/3/2024 GARO TELMI
Plan Check Approved 4/10/2024 GARO TELMI
Issued 4/10/2024 APPLICANT
Permit Finaled 10/7/2025 ALIZAH MAYAGOITIA

Permit Application Clearance Information

Street width determination Cleared 11/27/2023 DAVID LOPEZ
Address approval Cleared 11/28/2023 ADRIAN SANCHEZ
Specific Plan Cleared 11/29/2023 ANDREA MAGANA-WITHERS
BHO/Hillside ordinance Cleared 11/30/2023 ADRIAN SANCHEZ
Sewer availability Cleared 11/30/2023 ADRIAN SANCHEZ
Eng Process Fee Ord 176,300 Cleared 12/1/2023 ADRIAN SANCHEZ
Construction near power lines Cleared 2/10/2024 RIDWAN HARDY
Low Impact Development Cleared 2/23/2024 LUIS CRUZ
Miscellaneous Cleared 3/20/2024 DALIA MOKAYED
Roof/Waste drainage to street Cleared 3/21/2024 CHRISTINA BRACO
ZI Cleared 3/21/2024 DALIA MOKAYED

Contact Information

Architect Storey,, Simon Joseph; Lic. No.: C35346 2260 EARL ST      LOS ANGELES, CA 90039
Contractor Owner-Builder       ,
Engineer Darvasan-Stanciu,, George; Lic. No.: L7884 825 E COLTON AVE      REDLANDS, CA 92374
Engineer Lee,, Shyan-Chyun Tony; Lic. No.: C44045 17834 BAILEY DRIVE      TORRANCE, CA 90504
Engineer Phillips,, Craig; Lic. No.: C69673 2123 VESTAL AVE      LOS ANGELES, CA 90026

Inspector Information

OSVALDO PARAMO, (213) 202-9854 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 4/25/2024 Conditional Approval OSVALDO PARAMO
Excavation/Setback/Form/Re-Bar 4/29/2024 Partial Approval OSVALDO PARAMO
Footing/Foundation/Slab 4/29/2024 Partial Approval OSVALDO PARAMO
Underground Mechanical 6/25/2024 Partial Approval ALIZAH MAYAGOITIA
Floor/Roof Diaphrgm/Shear Wall 9/25/2024 Partial Approval ALIZAH MAYAGOITIA
ELECTRICAL-Rough 11/15/2024 Approved LUIS CASTRO
HVAC-Rough 11/15/2024 Not Ready for Inspection LUIS CASTRO
PLUMBING-Rough 11/15/2024 Approved LUIS CASTRO
BUILDING-Rough-Frame 11/26/2024 Corrections Issued THOMAS LOGRASSO
Green Building Rough 11/26/2024 Approved THOMAS LOGRASSO
HVAC-Rough 11/26/2024 Approved THOMAS LOGRASSO
Special/Order Compliance 11/26/2024 Corrections Issued THOMAS LOGRASSO
Verify Sprinkler Sign Off 11/26/2024 Approved THOMAS LOGRASSO
Insulation 12/13/2024 Approved JOSH MEISTER
Shower Pan 12/13/2024 Approved JOSH MEISTER
Interior/Exterior Lathing 3/7/2025 Partial Approval ALIZAH MAYAGOITIA
Drywall Nailing 6/26/2025 Approved REGINA MENDEZ
Interior/Exterior Lathing 8/1/2025 Corrections Issued GEM DE OCAMPO
Interior/Exterior Lathing 8/6/2025 Approved REGINA MENDEZ
Final 10/7/2025 Permit Finaled ALIZAH MAYAGOITIA
Green Building Final 10/7/2025 Approved ALIZAH MAYAGOITIA
Reinforced Masonry Frame 10/7/2025 Approved ALIZAH MAYAGOITIA
Smoke Detectors 10/7/2025 Approved ALIZAH MAYAGOITIA