21815 S NORMANDIE AVE 90501
Certificate Information: 21815 S NORMANDIE AVE 90501
- Application / Permit
- 18010-10000-00865
- Plan Check / Job No.
- B18LA03723
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- THREE STORY SINGLE FAMILY HOME WITH ATTACH TWO CAR GARAGE. Plan #4.
- Permit Issued
- Issued on 2/12/2020
- Issuing Office
- Metro
- Current Status
- CofO Issued on 3/15/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/2/2018 | APPLICANT |
| Green Plans Picked Up | 3/23/2018 | APPLICANT |
| Assigned to Plan Check Engineer | 3/29/2018 | TSE MING HUANG |
| Corrections Issued | 4/16/2018 | TSE MING HUANG |
| Quality Review Completed | 4/16/2018 | VERONICA LOPEZ |
| Plan Check Approved | 2/10/2020 | TSE MING HUANG |
| Issued | 2/12/2020 | LADBS |
| CofO in Progress | 3/8/2021 | JOHN KLARIN |
| Permit Finaled | 3/15/2021 | DEROLD HAUFF |
| CofO Issued | 3/15/2021 | DEROLD HAUFF |
| Permit Finaled | 3/15/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| Low Impact Development | Cleared | 6/8/2018 | MITESH PATEL |
| ZA Case | Cleared | 6/8/2018 | FIPE LEILUA |
| ZA Case | Cleared | 6/8/2018 | FIPE LEILUA |
| Address approval | Cleared | 6/14/2018 | NEIL TUANO |
| Highway dedication | Cleared | 6/14/2018 | NEIL TUANO |
| Permit | Cleared | 6/14/2018 | NEIL TUANO |
| Sewer availability | Cleared | 6/14/2018 | NEIL TUANO |
| Encroachment in public way | Cleared | 6/19/2018 | NEIL TUANO |
| Eng Process Fee Ord 176,300 | Cleared | 6/19/2018 | NEIL TUANO |
| Miscellaneous | Cleared | 6/19/2018 | NEIL TUANO |
| Roof/Waste drainage to street | Cleared | 6/19/2018 | NEIL TUANO |
| Construction near power lines | Cleared | 11/21/2018 | RIDWAN HARDY |
| Construction within easement | Cleared | 11/21/2018 | RIDWAN HARDY |
| Hydrant and Access approval | Cleared | 1/21/2020 | JOHN CONNEALLY |
| Green Code | Cleared | 1/29/2020 | NEGAR NEJAD |
Contact Information
| Architect | Knitter,, M J; Lic. No.: C10524 | 1401 DOVE STREET SUITE 240 NEWPORT BEACH, CA 92660 |
| Contractor | Pacific Communities Builder Inc; Lic. No.: 660968-B | 1000 DOVE STREET SUITE 100 NEWPORT BEACH, CA 92600 |
| Engineer | Ross, Scott William; Lic. No.: C45309 | 1800 E 16TH ST SANTA ANA, CA 92701 |
| Engineer | Toney,, Noelle Camille; Lic. No.: C84700 | 2085 HIGHPOINTE DRIVE UNIT 204 CORONA, CA 92879 |
| Landscape Architect | Dierking,, Ryan L.F; Lic. No.: LA5625 | 365 S PIXLEY STREET ORANGE, CA 92868 |
Inspector Information
| EUGENE CASSIDY, (310) 548-2508 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Sewer | 4/22/2020 | Partial Inspection | JOHN KLARIN |
| Underground Mechanical | 4/22/2020 | Partial Inspection | JOHN KLARIN |
| Excavation/Setback/Form/Re-Bar | 5/4/2020 | Approved | JOHN KLARIN |
| Footing/Foundation/Slab | 5/4/2020 | Approved | JOHN KLARIN |
| Reinforced Concrete Frame | 5/5/2020 | Approved | JOHN KLARIN |
| Floor/Roof Diaphrgm/Shear Wall | 6/2/2020 | Partial Inspection | JOHN KLARIN |
| Floor/Roof Diaphrgm/Shear Wall | 6/18/2020 | Partial Inspection | JOHN KLARIN |
| Floor/Roof Diaphrgm/Shear Wall | 7/10/2020 | Partial Approval | JOHN KLARIN |
| Floor/Roof Diaphrgm/Shear Wall | 7/17/2020 | Partial Inspection | JOHN KLARIN |
| BUILDING-Rough-Frame | 8/5/2020 | Conditional Approval | JOHN KLARIN |
| ELECTRICAL-Rough | 8/5/2020 | Approved | JOHN KLARIN |
| Green Building Rough | 8/5/2020 | Approved | JOHN KLARIN |
| HVAC-Rough | 8/5/2020 | Approved | JOHN KLARIN |
| PLUMBING-Rough | 8/5/2020 | Corrections Issued | JOHN KLARIN |
| Verify Sprinkler Sign Off | 8/5/2020 | Corrections Issued | JOHN KLARIN |
| BUILDING-Rough-Frame | 8/11/2020 | Approved | JOHN KLARIN |
| ELECTRICAL-Rough | 8/11/2020 | Approved | JOHN KLARIN |
| HVAC-Rough | 8/11/2020 | Approved | JOHN KLARIN |
| PLUMBING-Rough | 8/11/2020 | Approved | JOHN KLARIN |
| Verify Sprinkler Sign Off | 8/11/2020 | Approved | JOHN KLARIN |
| Interior/Exterior Lathing | 8/13/2020 | Approved | JOHN KLARIN |
| Interior/Exterior Lathing | 8/17/2020 | Approved | JOHN KLARIN |
| Drywall Nailing | 8/19/2020 | Approved | JOHN KLARIN |
| Gas Test | 9/15/2020 | Approved | JOHN KLARIN |
| ELECTRICAL-Final | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| Final | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| Green Building Final | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| PLUMBING-Final | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| SGSOV-Seismic Gas S/O Valve | 1/6/2021 | SGSOV Not Ready | JOHN KLARIN |
| Service/Power Release | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| Smoke Detectors | 1/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| ELECTRICAL-Final | 1/8/2021 | Approved | JOHN KLARIN |
| HVAC-Final | 1/8/2021 | Corrections Issued | JOHN KLARIN |
| PLUMBING-Final | 1/8/2021 | Approved | JOHN KLARIN |
| Service/Power Release | 1/8/2021 | Not Ready for Inspection | JOHN KLARIN |
| Final | 2/24/2021 | Not Ready for Inspection | JOHN KLARIN |
| Green Building Final | 2/24/2021 | Approved | JOHN KLARIN |
| SGSOV-Seismic Gas S/O Valve | 2/24/2021 | SGSOV Approved | JOHN KLARIN |
| Service/Power Release | 2/24/2021 | Not Ready for Inspection | JOHN KLARIN |
| Smoke Detectors | 2/24/2021 | Approved | JOHN KLARIN |
| Verify Rec and Parks Fee Memo | 2/24/2021 | Conditional Approval | JOHN KLARIN |
| Final | 3/5/2021 | OK to Issue CofO | JOHN KLARIN |
| HVAC-Final | 3/5/2021 | Approved | JOHN KLARIN |
| Service/Power Release | 3/5/2021 | Approved | JOHN KLARIN |