985 N EVERETT ST 90026
Certificate Information: 985 N EVERETT ST 90026
- Application / Permit
- 18010-10000-00029
- Plan Check / Job No.
- B17LA07039
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- New 2-story with basement: single family dwelling with attached garage in small lot development. (Lot 7 of 7 subdivided lots total). "Small lot subdivision pursuant to Tentative Tract Map No. 74363. A certificate of occupancy (temporary of final) shall not be issued until after the final map has been recorded."
- Permit Issued
- Issued on 9/20/2018
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 3/5/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/28/2017 | APPLICANT |
| Green Plans Picked Up | 6/6/2017 | APPLICANT |
| Disabled Access Plans Picked Up | 6/27/2017 | APPLICANT |
| Assigned to Plan Check Engineer | 11/22/2017 | JOSE RODRIGUEZ |
| Corrections Issued | 1/17/2018 | JOSE RODRIGUEZ |
| Quality Review Completed | 1/26/2018 | KAMRAN GHOTBI RAVANDI |
| Building Plans Picked Up | 1/29/2018 | APPLICANT |
| Applicant returned to address corrections | 2/22/2018 | JOSE RODRIGUEZ |
| Applicant returned to address corrections | 3/12/2018 | JOSE RODRIGUEZ |
| Applicant returned to address corrections | 3/22/2018 | JOSE RODRIGUEZ |
| Applicant returned to address corrections | 4/5/2018 | JOSE RODRIGUEZ |
| Plan Check Approved | 6/13/2018 | JOSE RODRIGUEZ |
| Issued | 9/20/2018 | LADBS |
| CofO in Progress | 3/4/2022 | SCOTT FINNILA |
| Permit Finaled | 3/5/2022 | DEROLD HAUFF |
| CofO Issued | 3/5/2022 | DEROLD HAUFF |
| Permit Finaled | 3/5/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Hydrant and Access approval | Cleared | 2/21/2018 | JOHN CONNEALLY |
| Address approval | Cleared | 2/28/2018 | CARLA VALLADARES |
| BHO/Hillside ordinance | Cleared | 2/28/2018 | CARLA VALLADARES |
| BHO/Hillside ordinance | Cleared | 2/28/2018 | CARLA VALLADARES |
| BHO/Hillside ordinance | Cleared | 2/28/2018 | CARLA VALLADARES |
| DAS Clearance | Cleared | 2/28/2018 | JOSE RODRIGUEZ |
| Permit | Cleared | 2/28/2018 | CARLA VALLADARES |
| GPI Written Notices | Cleared | 3/12/2018 | JOSE RODRIGUEZ |
| Grading Pre-Inspection | Cleared | 3/12/2018 | JOSE RODRIGUEZ |
| Green Code | Cleared | 3/12/2018 | JOSE RODRIGUEZ |
| Eng Process Fee Ord 176,300 | Cleared | 4/17/2018 | JAMES MORALEZ |
| Low Impact Development | Cleared | 4/17/2018 | SAM NAVID |
| Roof/Waste drainage to street | Cleared | 4/17/2018 | JAMES MORALEZ |
| Sewer availability | Cleared | 4/17/2018 | JAMES MORALEZ |
| "Q" conditions | Cleared | 5/25/2018 | NOAH MCCOY |
| Frnt yard landscape/Water mgmt | Cleared | 5/25/2018 | NOAH MCCOY |
| Tract Map conditions | Cleared | 5/25/2018 | JOSE RODRIGUEZ |
| Highway dedication | Cleared | 6/8/2018 | JAMES MORALEZ |
| Miscellaneous | Cleared | 6/8/2018 | TERRY PHAN |
Contact Information
| Architect | Moss, Kyle A; Lic. No.: C28077 | 2627 30TH STREET SANTA MONICA, CA 90405 |
| Contractor | I D C S Corporation; Lic. No.: 995061-B | 485 SOUTH ROBERTSON BLVD STE 8 BEVERLY HILLS, CA 90211 |
| Engineer | Babayan, Raffi Samuel; Lic. No.: C72168 | 1140 N COLUMBUS AVE 112 GLENDALE, CA 91202 |
| Engineer | Tosounian, Oshin Bedros; Lic. No.: S3730 | 7136 HASKELL AVE STE 301 VAN NUYS, CA 91406 |
| Geologist | Zweigler, Robert Ingraham; Lic. No.: EG1210 | 196 DIRT ROAD THOUSAND OAKS, CA 91361 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Piling/Pier/Caisson | 12/17/2018 | Partial Approval | SCOTT FINNILA |
| ELECTRICAL-Rough | 4/18/2019 | Partial Approval | SCOTT FINNILA |
| Footing/Foundation/Slab | 4/18/2019 | Partial Approval | SCOTT FINNILA |
| METHANE-Barrier | 4/18/2019 | Not Ready for Inspection | SCOTT FINNILA |
| METHANE-Subgrade | 4/18/2019 | Not Ready for Inspection | SCOTT FINNILA |
| Masonry Wall/Backfill | 5/3/2019 | Partial Approval | SCOTT FINNILA |
| Footing/Foundation/Slab | 5/10/2019 | Not Ready for Inspection | SCOTT FINNILA |
| METHANE-Barrier | 5/10/2019 | Not Ready for Inspection | SCOTT FINNILA |
| METHANE-Subgrade | 5/10/2019 | Not Ready for Inspection | SCOTT FINNILA |
| Excavation/Setback/Form/Re-Bar | 5/17/2019 | Conditional Approval | SCOTT FINNILA |
| Footing/Foundation/Slab | 5/23/2019 | Approved | SCOTT FINNILA |
| METHANE-Barrier | 5/23/2019 | Approved | SCOTT FINNILA |
| METHANE-Subgrade | 5/23/2019 | Approved | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 6/7/2019 | Partial Approval | SCOTT FINNILA |
| Drywall Nailing | 6/11/2019 | Partial Approval | SCOTT FINNILA |
| Green Building Rough | 6/11/2019 | Partial Approval | SCOTT FINNILA |
| Drywall Nailing | 6/28/2019 | Partial Approval | SCOTT FINNILA |
| Green Building Rough | 6/28/2019 | Partial Approval | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 7/9/2019 | Partial Approval | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 7/12/2019 | Partial Approval | SCOTT FINNILA |
| Drywall Nailing | 7/16/2019 | Partial Approval | SCOTT FINNILA |
| Green Building Rough | 7/16/2019 | Partial Approval | SCOTT FINNILA |
| Drywall Nailing | 8/8/2019 | Partial Approval | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 8/8/2019 | Partial Approval | SCOTT FINNILA |
| Green Building Rough | 8/8/2019 | Partial Approval | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 9/10/2019 | Corrections Issued | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 12/6/2019 | Partial Approval | SCOTT FINNILA |
| BUILDING-Rough-Frame | 12/10/2019 | Partial Approval | SCOTT FINNILA |
| ELECTRICAL-Rough | 12/10/2019 | Approved | SCOTT FINNILA |
| Green Building Rough | 12/10/2019 | Approved | SCOTT FINNILA |
| HVAC-Rough | 12/10/2019 | Approved | SCOTT FINNILA |
| METHANE-Rough | 12/10/2019 | Approved | SCOTT FINNILA |
| PLUMBING-Rough | 12/10/2019 | Approved | SCOTT FINNILA |
| Verify Sprinkler Sign Off | 12/10/2019 | Approved | SCOTT FINNILA |
| Insulation | 12/24/2019 | Approved | SCOTT FINNILA |
| Drywall Nailing | 12/31/2019 | Approved | SCOTT FINNILA |
| Interior/Exterior Lathing | 12/31/2019 | Approved | SCOTT FINNILA |
| Interior/Exterior Lathing | 1/2/2020 | Partial Approval | SCOTT FINNILA |
| Interior/Exterior Lathing | 1/30/2020 | Partial Approval | ALEJANDRO DE ARTOLA |
| Interior/Exterior Lathing | 1/31/2020 | Partial Approval | ALEJANDRO DE ARTOLA |
| Gas Test | 6/17/2020 | Partial Approval | SCOTT FINNILA |
| PLUMBING-Rough | 6/17/2020 | Corrections Issued | SCOTT FINNILA |
| Underground Mechanical | 9/2/2020 | Approved | ALEJANDRO DE ARTOLA |
| ELECTRICAL-Final | 12/23/2020 | Partial Inspection | SCOTT FINNILA |
| HVAC-Final | 12/23/2020 | Partial Inspection | SCOTT FINNILA |
| SGSOV-Seismic Gas S/O Valve | 12/23/2020 | SGSOV Approved | SCOTT FINNILA |
| Excavation/Setback/Form/Re-Bar | 1/25/2021 | Partial Approval | SCOTT FINNILA |
| Piling/Pier/Caisson | 1/25/2021 | Partial Approval | SCOTT FINNILA |
| Excavation/Setback/Form/Re-Bar | 2/17/2021 | Partial Approval | SCOTT FINNILA |
| Masonry Wall/Backfill | 2/17/2021 | Approved | SCOTT FINNILA |
| BUILDING-Rough-Frame | 5/21/2021 | Approved | SCOTT FINNILA |
| Final | 5/21/2021 | Corrections Issued | SCOTT FINNILA |
| Green Building Final | 5/21/2021 | Corrections Issued | SCOTT FINNILA |
| HVAC-Final | 5/21/2021 | Corrections Issued | SCOTT FINNILA |
| PLUMBING-Final | 5/21/2021 | Corrections Issued | SCOTT FINNILA |
| Service/Power Release | 5/21/2021 | Partial Inspection | SCOTT FINNILA |
| Smoke Detectors | 5/21/2021 | Corrections Issued | SCOTT FINNILA |
| ELECTRICAL-Final | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| Final | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| Green Building Final | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| HVAC-Final | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| PLUMBING-Final | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| Service/Power Release | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| Smoke Detectors | 6/9/2021 | Corrections Issued | SCOTT FINNILA |
| Final | 6/17/2021 | Corrections Issued | SCOTT FINNILA |
| Gas Test | 6/17/2021 | Corrections Issued | SCOTT FINNILA |
| Green Building Final | 6/17/2021 | Approved | SCOTT FINNILA |
| Service/Power Release | 6/17/2021 | Corrections Issued | SCOTT FINNILA |
| Smoke Detectors | 6/17/2021 | Approved | SCOTT FINNILA |
| Final | 6/22/2021 | Partial Inspection | SCOTT FINNILA |
| Service/Power Release | 6/22/2021 | Partial Inspection | SCOTT FINNILA |
| ELECTRICAL-Final | 6/25/2021 | Corrections Issued | SCOTT FINNILA |
| Final | 6/29/2021 | Corrections Issued | SCOTT FINNILA |
| Gas Test | 6/29/2021 | Partial Inspection | SCOTT FINNILA |
| Service/Power Release | 6/29/2021 | Partial Inspection | SCOTT FINNILA |
| Final | 1/3/2022 | Corrections Issued | SCOTT FINNILA |
| Service/Power Release | 1/3/2022 | Corrections Issued | SCOTT FINNILA |
| Special/Order Compliance | 1/3/2022 | Partial Inspection | ADAM ESCOTO |
| Service/Power Release | 2/9/2022 | Approved | ALEJANDRO DE ARTOLA |
| Final | 3/1/2022 | Partial Approval | SCOTT FINNILA |
| ELECTRICAL-Final | 3/4/2022 | Approved | SCOTT FINNILA |
| Final | 3/4/2022 | OK to Issue CofO | SCOTT FINNILA |
| HVAC-Final | 3/4/2022 | Approved | SCOTT FINNILA |
| PLUMBING-Final | 3/4/2022 | Approved | SCOTT FINNILA |