23017 W ELKWOOD ST 91304
Certificate Information: 23017 W ELKWOOD ST 91304
- Application / Permit
- 17016-20000-31828
- Plan Check / Job No.
- B17VN16349
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT EX DETACHED 2-CAR GARAGE INTO ACCESSORY DWELLING UNIT. SEE COMMENTS.
- Permit Issued
- Issued on 7/7/2020
- Issuing Office
- Current Status
- CofO Issued on 12/20/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/26/2017 | APPLICANT |
| Assigned to Plan Check Engineer | 11/2/2017 | HAYATO TSUCHIYA |
| Corrections Issued | 11/6/2017 | HAYATO TSUCHIYA |
| Quality Review Completed | 11/6/2017 | ABDUL CHEGENI |
| Building Plans Picked Up | 11/16/2017 | APPLICANT |
| Plan Check Approved | 6/17/2020 | HAYATO TSUCHIYA |
| Issued | 7/7/2020 | APPLICANT |
| CofO in Progress | 11/27/2023 | CHRIS CHRISTENSEN |
| Permit Finaled | 12/20/2023 | JOHN JANSON |
| CofO Issued | 12/20/2023 | JOHN JANSON |
| Permit Finaled | 12/20/2023 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 4/18/2018 | LEE GUILBEAUX |
| Sewer availability | Cleared | 4/18/2018 | LEE GUILBEAUX |
| Construction near power lines | Cleared | 8/8/2018 | RIDWAN HARDY |
| Hydrant and Access approval | Cleared | 10/2/2018 | JOHN DALLAS |
| Eng Process Fee Ord 176,300 | Cleared | 10/3/2018 | EDUARDO PEDROZA |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/14/2020 | Partial Approval | DAVID STEPANYAN |
| PLUMBING-Rough | 9/9/2020 | Partial Approval | DAVID STEPANYAN |
| Sewer | 9/9/2020 | Approved | DAVID STEPANYAN |
| Gas Test | 9/28/2020 | Partial Approval | DAVID STEPANYAN |
| Footing/Foundation/Slab | 11/5/2020 | Approved | DAVID STEPANYAN |
| Deputy Wood Construction | 10/1/2021 | No Access for Inspection | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 10/21/2021 | Corrections Issued | DAVID STEPANYAN |
| ELECTRICAL-Rough | 10/21/2021 | Corrections Issued | DAVID STEPANYAN |
| HVAC-Rough | 10/21/2021 | Corrections Issued | DAVID STEPANYAN |
| Interior/Exterior Lathing | 10/21/2021 | Partial Approval | DAVID STEPANYAN |
| PLUMBING-Rough | 10/21/2021 | Approved | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 2/28/2022 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Rough | 2/28/2022 | Corrections Issued | STEVEN BACK |
| HVAC-Rough | 2/28/2022 | Approved | STEVEN BACK |
| Shower Pan | 2/28/2022 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Rough | 3/29/2022 | Not Ready for Inspection | JESUS PINEDA |
| Shower Pan | 3/29/2022 | Approved | JESUS PINEDA |
| BUILDING-Rough-Frame | 5/9/2022 | Approved | CHRIS CHRISTENSEN |
| ELECTRICAL-Rough | 5/9/2022 | Approved | CHRIS CHRISTENSEN |
| Insulation | 6/7/2022 | Conditional Approval | JESUS PINEDA |
| Drywall Nailing | 7/18/2022 | Approved | CHRIS CHRISTENSEN |
| Green Building Rough | 7/18/2022 | Approved | CHRIS CHRISTENSEN |
| Final | 10/2/2023 | Corrections Issued | CHRIS CHRISTENSEN |
| Green Building Final | 10/2/2023 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| SGSOV-Seismic Gas S/O Valve | 10/2/2023 | SGSOV Not Ready | CHRIS CHRISTENSEN |
| Smoke Detectors | 10/2/2023 | Approved | CHRIS CHRISTENSEN |
| Final | 11/22/2023 | OK to Issue CofO | CHRIS CHRISTENSEN |
| Green Building Final | 11/22/2023 | Approved | CHRIS CHRISTENSEN |
| SGSOV-Seismic Gas S/O Valve | 11/22/2023 | SGSOV Approved | CHRIS CHRISTENSEN |