11979 W ROCHESTER AVE 90025
Certificate Information: 11979 W ROCHESTER AVE 90025
- Application / Permit
- 17016-10000-36594
- Plan Check / Job No.
- B17LA22564
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT-STORY SEISMIC RETROFIT PER LAMC DIVISION 93. INSTALLATION OF 2 ORDINARY MOMENT FRAME SYSTEMS (OMF) WITH CONCRETE TIE BEAM AT REAR (NORTH) AND WEST SIDE. WORKS ARE AT EXTERIOR OF WALLS, NOT ON TENANTS' UNITS.
- Permit Issued
- Issued on 9/28/2020
- Issuing Office
- Current Status
- CofC Issued on 10/15/2021
Permit Application Status History
| Submitted | 12/11/2017 | APPLICANT |
| Assigned to Plan Check Engineer | 1/4/2018 | ERWIN PASCUA |
| Corrections Issued | 1/8/2018 | ERWIN PASCUA |
| Quality Review Completed | 1/12/2018 | SAI KHUM |
| Building Plans Picked Up | 1/16/2018 | APPLICANT |
| Plan Check Approved | 1/30/2018 | ERWIN PASCUA |
| Issued | 9/28/2020 | APPLICANT |
| OK for CofC | 10/13/2021 | GRANT WOODS |
| CofC Issued | 10/15/2021 | TED RIES |
Permit Application Clearance Information
| Housing rent stabilization | Cleared | 8/27/2020 | STEVEN HOFSTAD |
Contact Information
| Contractor | B S C Development Inc; Lic. No.: 920184-B | P O BOX 8056 VAN NUYS, CA 91409 |
| Engineer | Leung, Colin Kam-Ming; Lic. No.: S5094 | 150 LAUREL AVE ARCADIA, CA 91006 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 10/13/2020 | Not Ready for Inspection | GRANT WOODS |
| Deputy Steel/Welding | 11/12/2020 | Conditional Approval | GRANT WOODS |
| Deputy Drilled-In Anchors | 11/20/2020 | Conditional Approval | GRANT WOODS |
| Footing/Foundation/Slab | 12/14/2020 | Corrections Issued | GRANT WOODS |
| Deputy Reinf. Concrete | 12/30/2020 | Approved | GRANT WOODS |
| Excavation/Setback/Form/Re-Bar | 12/30/2020 | Corrections Issued | GRANT WOODS |
| Wood Frame | 1/12/2021 | Approved | GRANT WOODS |
| Interior/Exterior Lathing | 1/26/2021 | Approved | GRANT WOODS |
| Final | 5/5/2021 | Conditional Approval | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 5/5/2021 | SGSOV Approved | GRANT WOODS |
| Smoke Detectors | 5/5/2021 | Approved | GRANT WOODS |
| Final | 10/13/2021 | OK for CofC | GRANT WOODS |