3900 N BERRY DR 91604

Certificate Information: 3900 N BERRY DR 91604

Application / Permit
17014-20000-06323
Plan Check / Job No.
B17VN18954
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PROPOSE 1ST AND 2ND STORY ADDITION TO (E) TWO STORY SFD AND REMODEL (SEE COMMENTS)
Permit Issued
Issued on 7/26/2018
Issuing Office
Valley
Current Status
CofO Issued on 4/2/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/11/2017 APPLICANT
Assigned to Plan Check Engineer 1/4/2018 DAWN MC NULTY
Green Plans Picked Up 1/8/2018 APPLICANT
Corrections Issued 1/16/2018 DAWN MC NULTY
Quality Review Completed 1/18/2018 CHON CHIO KUO
Building Plans Picked Up 1/19/2018 APPLICANT
Applicant returned to address corrections 7/16/2018 DAWN MC NULTY
Plan Check Approved 7/24/2018 DAWN MC NULTY
Issued 7/26/2018 LADBS
CofO in Progress 11/3/2023 CHRISTOPHE COCHRAN
CofO Issued 4/2/2024 RUBEN SALAS
Permit Finaled 4/2/2024 RUBEN SALAS

Permit Application Clearance Information

BHO/Hillside ordinance Cleared 1/31/2018 KENNETH PHAM
BHO/Hillside ordinance Cleared 1/31/2018 KENNETH PHAM
BHO/Hillside ordinance Cleared 1/31/2018 KENNETH PHAM
Eng Process Fee Ord 176,300 Cleared 1/31/2018 KENNETH PHAM
Permit Cleared 1/31/2018 KENNETH PHAM
Sewer availability Cleared 1/31/2018 KENNETH PHAM
Distance to fire station Cleared 5/3/2018 GILBERT URREA
Grading Pre-Inspection Cleared 7/16/2018 DAWN MC NULTY
Low Impact Development Cleared 7/19/2018 AMMAR ELTAWIL
Roof/Waste drainage to street Cleared 7/20/2018 JOHN LIN
Green Code Cleared 7/24/2018 DAVID MATSON

Contact Information

Contractor Santillana J Contractors; Lic. No.: 867431-B 11041 LOUISE AVENUE      LYNWOOD, CA 90262
Engineer , ; Lic. No.: S6000 15233 VENTURA BLVD   # 1130    SHERMAN OAKS, CA

Inspector Information

CHRISTOPHE COCHRAN, (818) 374-1165 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 8/3/2018 Approved CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 8/10/2018 Partial Approval CHRISTOPHE COCHRAN
PLUMBING-Rough 8/10/2018 Partial Approval CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 8/13/2018 Partial Approval CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 8/17/2018 Partial Approval CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 10/19/2018 Partial Approval JEFFREY PARD
Green Building Rough 10/19/2018 Approved JEFFREY PARD
PLUMBING-Rough 10/19/2018 Corrections Issued JEFFREY PARD
Rough-Elec/Plmb/HVAC 10/19/2018 Not Ready for Inspection JEFFREY PARD
Verify Sprinkler Sign Off 10/19/2018 Approved JEFFREY PARD
BUILDING-Rough-Frame 11/7/2018 Not Ready for Inspection JEFFREY PARD
ELECTRICAL-Rough 11/7/2018 Approved JEFFREY PARD
PLUMBING-Rough 11/7/2018 Approved JEFFREY PARD
HVAC-Rough 11/8/2018 Approved JEFFREY PARD
Light Gage Steel Frame 11/8/2018 Not Ready for Inspection JEFFREY PARD
BUILDING-Rough-Frame 11/13/2018 Approved JEFFREY PARD
Insulation 11/27/2018 Approved JEFFREY PARD
Drywall Nailing 12/7/2018 Approved CHRISTOPHE COCHRAN
Interior/Exterior Lathing 12/7/2018 Partial Approval CHRISTOPHE COCHRAN
Shower Pan 12/7/2018 Approved CHRISTOPHE COCHRAN
Final 8/9/2019 Corrections Issued RAYMOND KEHOE
Green Building Final 8/9/2019 Approved RAYMOND KEHOE
SGSOV-Seismic Gas S/O Valve 8/9/2019 SGSOV Approved RAYMOND KEHOE
Smoke Detectors 8/9/2019 Approved RAYMOND KEHOE
Final 9/20/2019 Corrections Issued RAYMOND KEHOE
Final 10/10/2023 Corrections Issued CHRISTOPHE COCHRAN
Final 10/17/2023 OK to Issue CofO CHRISTOPHE COCHRAN