8727 S BROADWAY 90003
Certificate Information: 8727 S BROADWAY 90003
- Application / Permit
- 17010-10011-05023
- Plan Check / Job No.
- B26LA21762
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Supplemental permit to 17010-10000-05023: Revised emergency exit route for a 76-unit, four-story apartment building currently under construction. This revision provides an alternate path of travel concrete sidewalk from the Ground Floor Units 105 and 106 to the north stair landing, exiting through the open-to-sky courtyard to the alley exit gate. The existing exit route through the lobby to Broadway will remain unchanged. The original egress path through the north side yard is not code-compliant for emergency exit access, as the gas meter projects into the required 48-inch minimum clear egress width. The building is 98% complete and completing final sign offs you urgent attention to this issues is appreciated
- Permit Issued
- Issued on 7/16/2026
- Issuing Office
- Current Status
- Permit Finaled on 7/20/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/1/2026 | APPLICANT |
| Assigned to Plan Check Engineer | 6/4/2026 | KESETE HAREGOT |
| Corrections Issued | 6/23/2026 | KESETE HAREGOT |
| Quality Review Completed | 7/2/2026 | ARMEN JIVALAGIAN |
| Plan Check Approved | 7/15/2026 | KESETE HAREGOT |
| Issued | 7/16/2026 | APPLICANT |
| Permit Finaled | 7/20/2026 | RAFAEL CORTES |
Permit Application Clearance Information
| Fire Marshal Fire Life Safety | Cleared | 7/7/2026 | MENOA AGHAJANI |
Contact Information
| Architect | Mutlow,, John V; Lic. No.: NA8816 | , |
| Contractor | Bernards Bros Inc; Lic. No.: 302007-B | 555 FIRST STREET SAN FERNANDO, CA 91340 |
Inspector Information
| PAUL BAZERKANIAN, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| LUIS CCAMACHO, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| ALAN MORELOS, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Final | 7/20/2026 | Permit Finaled | RAFAEL CORTES |