1854 S STONER AVE 90025

Certificate Information: 1854 S STONER AVE 90025

Application / Permit
16010-30000-05176
Plan Check / Job No.
B16WL05924
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Nnew construction of s.f.d. in small subdivision: unit 3 Small lot subdivision pursuant to Preliminary Parcel Map No. AA--2015-3434-PMLA-SL. A certificate of occupancy (temporary or final) shall not be issued until after the final map has been recorded. ************** 3 of 3 ******************************
Permit Issued
Issued on 3/16/2018
Issuing Office
West Los Angeles
Current Status
CofO Issued on 9/21/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 11/10/2016 APPLICANT
Assigned to Plan Check Engineer 12/15/2016 RICARDO RAMIREZ
Corrections Issued 12/22/2016 RICARDO RAMIREZ
Quality Review Completed 12/28/2016 STEVEN KIM
Building Plans Picked Up 12/29/2016 APPLICANT
Green Plans Picked Up 12/29/2016 APPLICANT
Applicant returned to address corrections 2/27/2017 RICARDO RAMIREZ
Applicant returned to address corrections 5/10/2017 RICARDO RAMIREZ
Plan Check Approved 2/7/2018 RICARDO RAMIREZ
Issued 3/16/2018 LADBS
CofO in Progress 9/21/2021 KENNETH NAGLE
Permit Finaled 9/21/2021 KENNETH NAGLE
CofO Issued 9/21/2021 KENNETH NAGLE
Permit Finaled 9/21/2021 KENNETH NAGLE

Permit Application Clearance Information

Watercourse Cleared 2/27/2017 OSCAR GUTIERREZ
Address approval Cleared 3/3/2017 HISASHI KOBAYAKAWA
CPC Cleared 4/20/2017 JESSE RAMOS
Hydrant and Access approval Cleared 4/25/2017 ROBERT DUFF
Low Impact Development Cleared 4/25/2017 AMMAR ELTAWIL
Roof/Waste drainage to street Cleared 4/25/2017 CARLA VALLADARES
Green Code Cleared 5/3/2017 BRYAN MEYER
Tract Map conditions Cleared 5/5/2017 BRIAN CARR
Eng Process Fee Ord 176,300 Cleared 5/10/2017 DENNIS BRAGIN
Sewer availability Cleared 5/10/2017 DENNIS BRAGIN
Miscellaneous Cleared 1/23/2018 TAO YANG

Contact Information

Architect Reiff, Brian A; Lic. No.: C27313 11816 LINDBLADE STREET      CULVER CITY, CA 90230
Contractor Ocean Spaulding Inc; Lic. No.: 833486-B 1061 NORTH SPAULDING AVENUE      LOS ANGELES, CA 90046
Engineer Mina, Joseph Wadie; Lic. No.: C53465 7247 DARNOCH WY      WEST HILLS, CA 91307

Inspector Information

ANTHONY EGSON, (310) 914-3893 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 5/1/2018 Partial Approval MICHAEL PELHAM
Pre-Inspection 5/1/2018 Partial Inspection MICHAEL PELHAM
Underground Mechanical 5/9/2018 Partial Approval MICHAEL PELHAM
FLOOD-Elevation Certificate 5/10/2018 Approved MICHAEL PELHAM
Footing/Foundation/Slab 5/10/2018 Partial Approval MICHAEL PELHAM
Deputy Reinf. Concrete 5/15/2018 Conditional Approval MICHAEL PELHAM
Footing/Foundation/Slab 7/5/2018 Approved MICHAEL PELHAM
Footing/Foundation/Slab 7/6/2018 No Result Entered VINCENT COTTON
Floor/Roof Diaphrgm/Shear Wall 9/14/2018 Approved ANTHONY MCDOWALL
Floor/Roof Diaphrgm/Shear Wall 9/21/2018 Approved ANTHONY MCDOWALL
Floor/Roof Diaphrgm/Shear Wall 10/18/2018 Approved ANTHONY MCDOWALL
Floor/Roof Diaphrgm/Shear Wall 10/29/2018 Approved ANTHONY MCDOWALL
Floor/Roof Diaphrgm/Shear Wall 11/19/2018 Approved ANTHONY MCDOWALL
ELECTRICAL-Rough 12/21/2018 Partial Inspection ANTHONY MCDOWALL
PLUMBING-Rough 2/7/2019 Not Ready for Inspection EVAN COOPER
ELECTRICAL-Rough 3/8/2019 Partial Approval EVAN COOPER
HVAC-Rough 3/8/2019 Partial Approval EVAN COOPER
PLUMBING-Rough 3/8/2019 Approved EVAN COOPER
ELECTRICAL-Rough 3/13/2019 Not Ready for Inspection ROBERT VORHIS
Floor/Roof Diaphrgm/Shear Wall 3/13/2019 Partial Approval ROBERT VORHIS
HVAC-Rough 3/13/2019 Partial Inspection ROBERT VORHIS
Verify Sprinkler Sign Off 3/13/2019 Not Ready for Inspection ROBERT VORHIS
ELECTRICAL-Rough 3/20/2019 Approved EVAN COOPER
HVAC-Rough 3/20/2019 Approved EVAN COOPER
Shower Pan 3/20/2019 Not Ready for Inspection EVAN COOPER
BUILDING-Rough-Frame 3/27/2019 Conditional Approval KEVIN BEAULIEU
FLOOD-Proofing Certificate 3/27/2019 OK to Expire Permit KEVIN BEAULIEU
Green Building Rough 3/27/2019 Approved KEVIN BEAULIEU
Interior/Exterior Lathing 3/27/2019 Not Ready for Inspection KEVIN BEAULIEU
Verify Sprinkler Sign Off 3/27/2019 Approved KEVIN BEAULIEU
Insulation 4/2/2019 Approved EVAN COOPER
Interior/Exterior Lathing 4/2/2019 Not Ready for Inspection EVAN COOPER
Shower Pan 4/2/2019 Approved EVAN COOPER
Drywall Nailing 4/19/2019 Approved EVAN COOPER
Interior/Exterior Lathing 6/12/2019 Approved EVAN COOPER
Masonry Wall/Backfill 1/22/2020 No Access for Inspection OGANES TARAKHCHYAN
Masonry Wall/Backfill 1/28/2020 Not Ready for Inspection OGANES TARAKHCHYAN
Special/Order Compliance 3/4/2020 Not Ready for Inspection OGANES TARAKHCHYAN
HVAC-Final 6/30/2021 Approved OGANES TARAKHCHYAN
BUILDING-Rough-Frame 7/19/2021 Partial Approval OGANES TARAKHCHYAN
FLOOD-Proofing Certificate 7/19/2021 Not Ready for Inspection OGANES TARAKHCHYAN
Final 7/19/2021 Partial Inspection OGANES TARAKHCHYAN
Green Building Final 7/19/2021 Approved OGANES TARAKHCHYAN
SGSOV-Seismic Gas S/O Valve 7/19/2021 SGSOV Approved OGANES TARAKHCHYAN
Service/Power Release 7/19/2021 Not Ready for Inspection OGANES TARAKHCHYAN
Structural Steel Frame 7/19/2021 Not Ready for Inspection OGANES TARAKHCHYAN
BUILDING-Rough-Frame 8/6/2021 Approved OGANES TARAKHCHYAN
FLOOD-Proofing Certificate 8/6/2021 Approved OGANES TARAKHCHYAN
Final 8/6/2021 Partial Approval OGANES TARAKHCHYAN
Service/Power Release 8/6/2021 Approved OGANES TARAKHCHYAN
Structural Steel Frame 8/6/2021 Approved OGANES TARAKHCHYAN