17543 W TRAMONTO DR 90272
Certificate Information: 17543 W TRAMONTO DR 90272
- Application / Permit
- 16010-30000-03472
- Plan Check / Job No.
- B16WL04029
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- new two-story building with attached garage
- Permit Issued
- Issued on 4/30/2018
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 6/1/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/5/2016 | APPLICANT |
| Assigned to Plan Check Engineer | 8/25/2016 | SHANGQIN XIE |
| Green Plans Picked Up | 8/26/2016 | APPLICANT |
| Corrections Issued | 8/30/2016 | SHANGQIN XIE |
| Quality Review Completed | 8/31/2016 | STEVEN KIM |
| Building Plans Picked Up | 8/31/2016 | APPLICANT |
| Applicant returned to address corrections | 9/13/2016 | SHANGQIN XIE |
| Applicant returned to address corrections | 5/11/2017 | SHANGQIN XIE |
| Plan Check Approved | 4/19/2018 | SHANGQIN XIE |
| Issued | 4/30/2018 | LADBS |
| CofO in Progress | 5/26/2023 | GERMAN RODRIGUEZ MENDOZA |
| Permit Finaled | 6/1/2023 | DANIEL ORRANTE |
| CofO Issued | 6/1/2023 | DANIEL ORRANTE |
| Permit Finaled | 6/1/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 2/1/2017 | ERIK MUNOZ |
| BHO/Hillside ordinance | Cleared | 2/1/2017 | ERIK MUNOZ |
| BHO/Hillside ordinance | Cleared | 2/1/2017 | ERIK MUNOZ |
| BHO/Hillside ordinance | Cleared | 2/1/2017 | ERIK MUNOZ |
| Eng Process Fee Ord 176,300 | Cleared | 2/1/2017 | ERIK MUNOZ |
| Hydrant and Access approval | Cleared | 2/1/2017 | GILBERT URREA |
| Miscellaneous | Cleared | 2/1/2017 | ERIK MUNOZ |
| Permit | Cleared | 2/1/2017 | ERIK MUNOZ |
| Sewer availability | Cleared | 2/1/2017 | ERIK MUNOZ |
| Low Impact Development | Cleared | 2/13/2017 | SAM NAVID |
| Roof/Waste drainage to street | Cleared | 2/13/2017 | RAVIL MANAPOV |
| Green Code | Cleared | 4/28/2017 | RICHARD GARCIA |
| Miscellaneous | Cleared | 5/2/2017 | KEVIN AZARMAHAN |
| Coastal Zone | Cleared | 4/11/2018 | TREVOR MARTIN |
| Coastal Zone | Cleared | 4/11/2018 | TREVOR MARTIN |
| Coastal Zone | Cleared | 4/11/2018 | TREVOR MARTIN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Hollingsworth, Robert Alan; Lic. No.: GE2022 | 31129 VIA COLINAS SUITE 707 WESTLAKE VILLAGE, CA 91362 |
| Engineer | Javadi-Koma, Shahram; Lic. No.: C69497 | 10349 MONTGOMERY AVE GRANADA HILLS, CA 91403 |
| Geologist | Hollingsworth, Robert Alan; Lic. No.: EG1265 | 31129 VIA COLINAS SUITE 707 WESTLAKE VILLAGE, CA 91362 |
Inspector Information
| DANIEL VERA, (213) 577-9924 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 10/12/2018 | No Access for Inspection | MICHAEL PELHAM |
| Pre-Inspection | 10/16/2018 | Partial Inspection | MICHAEL PELHAM |
| Footing/Foundation/Slab | 4/10/2019 | Partial Inspection | ANDREW NAVE |
| Footing/Foundation/Slab | 4/22/2019 | Partial Approval | ANDREW NAVE |
| Piling/Pier/Caisson | 4/26/2019 | Partial Approval | ANDREW NAVE |
| Piling/Pier/Caisson | 5/1/2019 | Partial Approval | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 5/20/2019 | Partial Approval | ANDREW NAVE |
| Special/Order Compliance | 8/5/2019 | Approved | ANDREW NAVE |
| Footing/Foundation/Slab | 8/9/2019 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 8/19/2019 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 8/23/2019 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 9/18/2019 | Corrections Issued | ANDREW NAVE |
| PLUMBING-Rough | 12/17/2019 | Partial Approval | ANDREW NAVE |
| Special/Order Compliance | 12/17/2019 | Corrections Issued | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 12/20/2019 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 12/20/2019 | Corrections Issued | ANDREW NAVE |
| PLUMBING-Rough | 1/23/2020 | Not Ready for Inspection | ANDREW NAVE |
| Deputy Reinf. Concrete | 4/1/2020 | Approved | ANDREW NAVE |
| BUILDING-Rough-Frame | 4/9/2020 | Partial Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 4/13/2020 | Conditional Approval | ANDREW NAVE |
| ELECTRICAL-Rough | 4/24/2020 | Partial Approval | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 4/24/2020 | Partial Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 4/28/2020 | Conditional Approval | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 5/15/2020 | Corrections Issued | ANDREW NAVE |
| Deputy Drilled-In Anchors | 5/29/2020 | Approved | ANDREW NAVE |
| Deputy Reinf. Concrete | 5/29/2020 | Approved | ANDREW NAVE |
| Deputy Steel/Welding | 5/29/2020 | Approved | ROBERT SHELLY |
| Reinforced Concrete Frame | 5/29/2020 | Partial Approval | ANDREW NAVE |
| Deputy Drilled-In Anchors | 6/2/2020 | Conditional Approval | ANDREW NAVE |
| Reinforced Concrete Frame | 6/12/2020 | Partial Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 6/15/2020 | Conditional Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 6/16/2020 | Conditional Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 6/26/2020 | Approved | ANDREW NAVE |
| Footing/Foundation/Slab | 6/26/2020 | Partial Approval | ANDREW NAVE |
| Deputy Reinf. Masonry | 6/30/2020 | Conditional Approval | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 8/4/2020 | Partial Approval | ANDREW NAVE |
| Deputy Reinf. Concrete | 8/6/2020 | Approved | ROBERT SHELLY |
| Deputy Shotcrete | 8/12/2020 | Conditional Approval | ANDREW NAVE |
| Deputy Drilled-In Anchors | 8/26/2020 | Conditional Approval | ANDREW NAVE |
| Deputy Drilled-In Anchors | 10/27/2020 | Conditional Approval | ANDREW NAVE |
| Deputy Drilled-In Anchors | 11/20/2020 | Conditional Approval | ANDREW NAVE |
| Underground Mechanical | 12/11/2020 | Partial Approval | ANDREW NAVE |
| PLUMBING-Rough | 12/22/2020 | Not Ready for Inspection | PIERRE VEGA |
| HVAC-Rough | 12/29/2020 | Corrections Issued | JOHNNY MIRANDA |
| PLUMBING-Rough | 1/12/2021 | Approved | ANDREW NAVE |
| Underground Mechanical | 3/10/2021 | Approved | ANDREW NAVE |
| HVAC-Rough | 3/22/2021 | Corrections Issued | ANDREW NAVE |
| ELECTRICAL-Rough | 3/25/2021 | Corrections Issued | ANDREW NAVE |
| HVAC-Rough | 4/13/2021 | Partial Approval | ANDREW NAVE |
| ELECTRICAL-Rough | 4/23/2021 | Approved | ANDREW NAVE |
| HVAC-Rough | 4/23/2021 | Approved | ANDREW NAVE |
| Verify Sprinkler Sign Off | 4/29/2021 | Not Ready for Inspection | ANDREW NAVE |
| Wood Frame | 4/29/2021 | Not Ready for Inspection | ANDREW NAVE |
| Shower Pan | 5/21/2021 | Approved | ANDREW NAVE |
| Drywall Nailing | 5/28/2021 | Partial Approval | ANDREW NAVE |
| Green Building Rough | 5/28/2021 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 6/11/2021 | No Access for Inspection | KENNETH NAGLE |
| Service/Power Release | 12/21/2021 | Not Ready for Inspection | ANDREW NAVE |
| ELECTRICAL-Final | 1/18/2022 | Approved | ANDREW NAVE |
| Service/Power Release | 1/24/2022 | Approved | MICHAEL PELHAM |
| Gas Test | 2/4/2022 | Corrections Issued | ANDREW NAVE |
| PLUMBING-Final | 2/4/2022 | Corrections Issued | ANDREW NAVE |
| Gas Test | 2/16/2022 | Approved | ANDREW NAVE |
| PLUMBING-Final | 2/16/2022 | Corrections Issued | ANDREW NAVE |
| Gas Test | 6/13/2022 | Approved | ANDREW NAVE |
| Underground Mechanical | 7/28/2022 | Not Ready for Inspection | BRENDAN LOONEY |
| HVAC-Final | 8/31/2022 | Corrections Issued | BRENDAN LOONEY |
| PLUMBING-Final | 8/31/2022 | Not Ready for Inspection | BRENDAN LOONEY |
| Sewer | 8/31/2022 | Not Ready for Inspection | BRENDAN LOONEY |
| HVAC-Final | 5/4/2023 | Not Ready for Inspection | BRENDAN LOONEY |
| PLUMBING-Final | 5/4/2023 | Corrections Issued | BRENDAN LOONEY |
| PLUMBING-Final | 5/16/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| BUILDING-Rough-Frame | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Drywall Nailing | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Final | 5/19/2023 | Conditional Approval | GERMAN RODRIGUEZ MENDOZA |
| Footing/Foundation/Slab | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Green Building Final | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Reinforced Concrete Frame | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| SGSOV-Seismic Gas S/O Valve | 5/19/2023 | SGSOV Approved | GERMAN RODRIGUEZ MENDOZA |
| Smoke Detectors | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Structural Steel Frame | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Verify Sprinkler Sign Off | 5/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |