316 S CARMELINA AVE 90049
Certificate Information: 316 S CARMELINA AVE 90049
- Application / Permit
- 16010-20000-01930
- Plan Check / Job No.
- B16VN06386
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSED IRR TWO STORY SFD WITH HABITABLE BASEMENT.
- Permit Issued
- Issued on 11/9/2017
- Issuing Office
- West Los Angeles
- Current Status
- Issued on 11/9/2017
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 5/12/2016 | APPLICANT |
| Assigned to Plan Check Engineer | 5/26/2016 | DOUGLAS NAKATANI |
| Corrections Issued | 6/1/2016 | DOUGLAS NAKATANI |
| Quality Review Completed | 6/2/2016 | KAMRAN GHOTBI RAVANDI |
| Building Plans Picked Up | 6/3/2016 | APPLICANT |
| Green Plans Picked Up | 6/3/2016 | APPLICANT |
| Applicant returned to address corrections | 6/15/2017 | DOUGLAS NAKATANI |
| Applicant returned to address corrections | 9/13/2017 | DOUGLAS NAKATANI |
| Applicant returned to address corrections | 10/24/2017 | DOUGLAS NAKATANI |
| Plan Check Approved | 11/3/2017 | DOUGLAS NAKATANI |
| Issued | 11/9/2017 | LADBS |
Permit Application Clearance Information
| Address approval | Cleared | 9/18/2017 | OSCAR GUTIERREZ |
| Eng Process Fee Ord 176,300 | Cleared | 9/18/2017 | OSCAR GUTIERREZ |
| Sewer availability | Cleared | 9/18/2017 | OSCAR GUTIERREZ |
| Green Code | Cleared | 9/21/2017 | MICHAEL AYERS |
| Hydrant and Access approval | Cleared | 9/26/2017 | JOHN CONNEALLY |
| Low Impact Development | Cleared | 9/28/2017 | SAM NAVID |
| Excavation more than 5-ft deep | Cleared | 10/24/2017 | CALOSHA APPROVED |
| Roof/Waste drainage to street | Cleared | 10/24/2017 | HISASHI KOBAYAKAWA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Almalla, Dean; Lic. No.: C58024 | 15053 VENTURA BLVD STE 205 SHERMAN OAKS, CA 91403 |
Inspector Information
| HERBERT GIRON, (310) 914-3891 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 5/3/2018 | Partial Inspection | VINCENT SCIPIONI |
| Piling/Pier/Caisson | 5/14/2018 | Not Ready for Inspection | VINCENT SCIPIONI |
| Footing/Foundation/Slab | 7/27/2018 | Corrections Issued | VINCENT SCIPIONI |
| Excavation/Setback/Form/Re-Bar | 8/7/2018 | Corrections Issued | VINCENT SCIPIONI |
| Footing/Foundation/Slab | 8/7/2018 | Partial Approval | VINCENT SCIPIONI |
| Footing/Foundation/Slab | 8/16/2018 | Partial Approval | VINCENT SCIPIONI |
| Excavation/Setback/Form/Re-Bar | 9/25/2018 | Corrections Issued | VINCENT SCIPIONI |
| Footing/Foundation/Slab | 9/28/2018 | Partial Approval | VINCENT SCIPIONI |
| PLUMBING-Rough | 10/9/2018 | Partial Approval | MICHAEL PELHAM |
| Footing/Foundation/Slab | 11/5/2018 | Corrections Issued | DANIEL ORRANTE |
| Excavation/Setback/Form/Re-Bar | 11/8/2018 | Approved | DANIEL ORRANTE |
| Footing/Foundation/Slab | 11/9/2018 | Not Ready for Inspection | MICHAEL PELHAM |
| Footing/Foundation/Slab | 4/8/2019 | Partial Approval | RICHARD STEINBACH |
| Underground Mechanical | 4/8/2019 | Partial Approval | RICHARD STEINBACH |
| Deputy Reinf. Concrete | 4/15/2019 | Conditional Approval | MICHAEL TEMPLE |
| Deputy Reinf. Concrete | 4/18/2019 | Conditional Approval | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 6/5/2019 | Not Ready for Inspection | MICHAEL TEMPLE |
| Floor/Roof Diaphrgm/Shear Wall | 6/5/2019 | Partial Approval | MICHAEL TEMPLE |
| Green Building Rough | 6/5/2019 | Not Ready for Inspection | MICHAEL TEMPLE |
| Verify Sprinkler Sign Off | 6/5/2019 | Not Ready for Inspection | MICHAEL TEMPLE |
| Footing/Foundation/Slab | 9/3/2019 | Corrections Issued | TIM CHRISTENSEN |
| Underground Mechanical | 9/3/2019 | Not Ready for Inspection | TIM CHRISTENSEN |
| Footing/Foundation/Slab | 9/11/2019 | Partial Approval | DANNY TOLENTINO |
| Underground Mechanical | 9/11/2019 | Not Ready for Inspection | DANNY TOLENTINO |
| Footing/Foundation/Slab | 9/26/2019 | Approved | TIM CHRISTENSEN |
| Sewer | 12/18/2019 | Partial Approval | TIM CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 1/8/2020 | Corrections Issued | DANNY TOLENTINO |
| Deputy Wood Construction | 8/21/2020 | Corrections Issued | ROBERT SHELLY |
| Floor/Roof Diaphrgm/Shear Wall | 8/24/2020 | Partial Approval | TIM CHRISTENSEN |
| ELECTRICAL-Rough | 8/25/2020 | Approved | JOHN KIDWELL |
| HVAC-Rough | 9/8/2020 | Not Ready for Inspection | JOHN KIDWELL |
| HVAC-Rough | 9/14/2020 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| PLUMBING-Rough | 9/14/2020 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| HVAC-Rough | 9/21/2020 | Approved | JOHN KIDWELL |
| PLUMBING-Rough | 9/21/2020 | Approved | JOHN KIDWELL |
| BUILDING-Rough-Frame | 11/16/2020 | Approved | JOHN KIDWELL |
| Green Building Rough | 11/16/2020 | Approved | JOHN KIDWELL |
| Interior/Exterior Lathing | 11/16/2020 | Partial Approval | JOHN KIDWELL |
| Verify Sprinkler Sign Off | 11/16/2020 | Approved | JOHN KIDWELL |
| Insulation | 6/21/2021 | Approved | JOHN KIDWELL |
| PLUMBING-Rough | 6/21/2021 | Partial Approval | JOHN KIDWELL |
| Drywall Nailing | 7/12/2021 | Approved | JOHN KIDWELL |
| Shower Pan | 8/17/2021 | Approved | JOHN KIDWELL |
| Underground Mechanical | 11/3/2021 | Partial Approval | JOHN KIDWELL |
| Interior/Exterior Lathing | 12/7/2021 | Approved | JUAN VALENZUELA |
| PLUMBING-Rough | 7/20/2023 | Corrections Issued | KEVIN SARGSYAN |
| Special/Order Compliance | 7/25/2023 | Corrections Issued | OGANES TARAKHCHYAN |
| Rough-Elec/Plmb/HVAC | 4/24/2026 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Final | 5/8/2026 | No Access for Inspection | KEVIN SARGSYAN |
| HVAC-Final | 5/19/2026 | Partial Approval | HERBERT GIRON |