4235 N CORONA DR 90032
Certificate Information: 4235 N CORONA DR 90032
- Application / Permit
- 16010-10000-04685
- Plan Check / Job No.
- B16LA15746
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 2-STORY HILLSIDE AREA (ZONING CODE) SFD WITH BASEMENT GARAGE
- Permit Issued
- Issued on 10/12/2018
- Issuing Office
- Metro
- Current Status
- CofO Issued on 1/30/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/12/2016 | APPLICANT |
| Green Plans Picked Up | 11/17/2016 | APPLICANT |
| Assigned to Plan Check Engineer | 11/22/2016 | BIDYUT RATH |
| Corrections Issued | 12/5/2016 | BIDYUT RATH |
| Quality Review Completed | 12/7/2016 | LARRY LEE |
| Building Plans Picked Up | 12/12/2016 | APPLICANT |
| Applicant returned to address corrections | 3/9/2017 | BIDYUT RATH |
| Applicant returned to address corrections | 6/26/2018 | BIDYUT RATH |
| Applicant returned to address corrections | 7/18/2018 | BIDYUT RATH |
| Applicant returned to address corrections | 7/23/2018 | BIDYUT RATH |
| Applicant returned to address corrections | 9/11/2018 | BIDYUT RATH |
| Plan Check Approved | 10/11/2018 | BIDYUT RATH |
| Issued | 10/12/2018 | LADBS |
| CofO in Progress | 1/26/2024 | AMY COLIN |
| Permit Finaled | 1/30/2024 | DEROLD HAUFF |
| CofO Issued | 1/30/2024 | DEROLD HAUFF |
| Permit Finaled | 1/30/2024 | DEROLD HAUFF |
Permit Application Clearance Information
| "D" conditions | Cleared | 12/29/2016 | MARY RICHARDSON |
| "Q" conditions | Cleared | 12/29/2016 | MARY RICHARDSON |
| ZI | Cleared | 12/29/2016 | MARY RICHARDSON |
| ZI | Cleared | 12/29/2016 | MARY RICHARDSON |
| Green Code | Cleared | 3/1/2017 | BIDYUT RATH |
| Grading Pre-Inspection | Cleared | 3/9/2017 | BIDYUT RATH |
| Disturb/Remove Protected Trees | Cleared | 3/31/2017 | LUIS TORRES |
| Green Code | Cleared | 7/18/2018 | BIDYUT RATH |
| Address approval | Cleared | 7/24/2018 | MICHAEL CASTILLO |
| Hydrant and Access approval | Cleared | 7/24/2018 | GEORGE SUCHAND |
| Miscellaneous | Cleared | 7/24/2018 | GEORGE SUCHAND |
| Permit | Cleared | 7/24/2018 | MICHAEL CASTILLO |
| Low Impact Development | Cleared | 7/30/2018 | ANDRES COVARRUBIAS |
| BHO/Hillside ordinance | Cleared | 8/6/2018 | ADRIAN SANCHEZ |
| BHO/Hillside ordinance | Cleared | 8/6/2018 | ADRIAN SANCHEZ |
| Eng Process Fee Ord 176,300 | Cleared | 8/6/2018 | ADRIAN SANCHEZ |
| Roof/Waste drainage to street | Cleared | 8/6/2018 | ADRIAN SANCHEZ |
| Sewer availability | Cleared | 8/6/2018 | ADRIAN SANCHEZ |
| "D" conditions | Cleared | 8/15/2018 | NICOLE SANCHEZ |
| "Q" conditions | Cleared | 8/15/2018 | NICOLE SANCHEZ |
| ZI | Cleared | 8/15/2018 | NICOLE SANCHEZ |
| BHO/Hillside ordinance | Cleared | 9/25/2018 | STEVE MELGAR |
Contact Information
| Contractor | C E M Construction Corporation; Lic. No.: 951234-B | 8207 BROOKGREEN ROAD DOWNEY, CA 90240 |
| Engineer | , ; Lic. No.: C86223 | 1840 S GAFFEY STREET 382 SAN PEDRO, CA 90731 |
| Engineer | Carrillo, Jesus Eduardo; Lic. No.: C77737 | 8207 BROOKGREEN RD DOWNEY, CA 90240 |
| Geologist | , ; Lic. No.: EG1314 | 501 VALIDO ROAD ARCADIA, CA 91007 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Special/Order Compliance | 5/18/2021 | Approved | COREY HUPP |
| Footing/Foundation/Slab | 7/1/2021 | Corrections Issued | COREY HUPP |
| Special/Order Compliance | 7/1/2021 | Approved | COREY HUPP |
| Footing/Foundation/Slab | 7/30/2021 | Partial Approval | COREY HUPP |
| Footing/Foundation/Slab | 8/30/2021 | Partial Approval | SCOTT FINNILA |
| Footing/Foundation/Slab | 9/2/2021 | Corrections Issued | JOAQUIN GREENOUGH |
| BUILDING-Rough-Frame | 9/4/2021 | Off-Hour Fees Due | |
| Green Building Rough | 9/7/2021 | Not Ready for Inspection | JOAQUIN GREENOUGH |
| Reinforced Concrete Frame | 9/7/2021 | Partial Approval | JOAQUIN GREENOUGH |
| Verify Sprinkler Sign Off | 9/7/2021 | Not Ready for Inspection | JOAQUIN GREENOUGH |
| Deputy Reinf. Concrete | 9/9/2021 | Partial Approval | RUBEN SALAS |
| Footing/Foundation/Slab | 9/16/2021 | Partial Approval | COREY HUPP |
| Masonry Wall/Backfill | 10/20/2021 | Partial Inspection | COREY HUPP |
| Footing/Foundation/Slab | 1/6/2022 | Partial Approval | RUBEN SALAS |
| PLUMBING-Rough | 1/12/2022 | Approved | COREY HUPP |
| Footing/Foundation/Slab | 1/24/2022 | Partial Approval | OSVALDO PARAMO |
| PLUMBING-Rough | 1/24/2022 | Partial Approval | OSVALDO PARAMO |
| Footing/Foundation/Slab | 2/2/2022 | Partial Approval | OSVALDO PARAMO |
| Deputy Reinf. Concrete | 2/3/2022 | Conditional Approval | MICHAEL LEWIS |
| Special/Order Compliance | 2/3/2022 | Approved | MICHAEL LEWIS |
| Excavation/Setback/Form/Re-Bar | 2/23/2022 | Corrections Issued | COREY HUPP |
| Footing/Foundation/Slab | 3/2/2022 | Approved | COREY HUPP |
| Deputy Reinf. Concrete | 3/4/2022 | Conditional Approval | COREY HUPP |
| PLUMBING-Rough | 3/23/2022 | Approved | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 4/25/2022 | Corrections Issued | AMY COLIN |
| Special/Order Compliance | 7/15/2022 | Corrections Issued | AMY COLIN |
| Special/Order Compliance | 7/15/2022 | Partial Inspection | AMY COLIN |
| Special/Order Compliance | 9/29/2022 | Partial Inspection | AMY COLIN |
| BUILDING-Rough-Frame | 10/25/2022 | Not Ready for Inspection | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 10/25/2022 | Corrections Issued | AMY COLIN |
| Green Building Rough | 10/25/2022 | Not Ready for Inspection | AMY COLIN |
| Verify Sprinkler Sign Off | 10/25/2022 | Corrections Issued | AMY COLIN |
| BUILDING-Rough-Frame | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| ELECTRICAL-Rough | 11/1/2022 | Corrections Issued | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| Green Building Rough | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| HVAC-Rough | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| PLUMBING-Rough | 11/1/2022 | Corrections Issued | AMY COLIN |
| Rough-Elec/Plmb/HVAC | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| Verify Sprinkler Sign Off | 11/1/2022 | Not Ready for Inspection | AMY COLIN |
| Wood Frame | 11/1/2022 | Corrections Issued | AMY COLIN |
| ELECTRICAL-Rough | 11/18/2022 | Approved | AMY COLIN |
| Gas Test | 11/18/2022 | Approved | AMY COLIN |
| HVAC-Rough | 11/18/2022 | Approved | AMY COLIN |
| PLUMBING-Rough | 11/18/2022 | Approved | AMY COLIN |
| Rough-Elec/Plmb/HVAC | 11/18/2022 | Approved | AMY COLIN |
| BUILDING-Rough-Frame | 11/23/2022 | Partial Inspection | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 11/23/2022 | Corrections Issued | AMY COLIN |
| Green Building Rough | 11/23/2022 | Not Ready for Inspection | AMY COLIN |
| Verify Sprinkler Sign Off | 11/23/2022 | Corrections Issued | AMY COLIN |
| Deputy Wood Construction | 11/30/2022 | Conditional Approval | AMY COLIN |
| Deputy Wood Construction | 12/1/2022 | Approved | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 12/1/2022 | Approved | AMY COLIN |
| Wood Frame | 12/1/2022 | Approved | AMY COLIN |
| Special/Order Compliance | 1/10/2023 | Approved | AMY COLIN |
| BUILDING-Rough-Frame | 2/15/2023 | Approved | ALIZAH MAYAGOITIA |
| Verify Sprinkler Sign Off | 2/15/2023 | Approved | ALIZAH MAYAGOITIA |
| ELECTRICAL-Final | 6/7/2023 | Not Ready for Inspection | AMY COLIN |
| Service/Power Release | 8/26/2023 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
| BUILDING-Rough-Frame | 11/17/2023 | Approved | ROY SPAULDING |
| Final | 11/17/2023 | Corrections Issued | ROY SPAULDING |
| Green Building Final | 11/17/2023 | Not Ready for Inspection | ROY SPAULDING |
| Green Building Rough | 11/17/2023 | Approved | ROY SPAULDING |
| Reinforced Concrete Frame | 11/17/2023 | Approved | ROY SPAULDING |
| SGSOV-Seismic Gas S/O Valve | 11/17/2023 | SGSOV No Gas | ROY SPAULDING |
| Service/Power Release | 11/17/2023 | Not Ready for Inspection | ROY SPAULDING |
| Smoke Detectors | 11/17/2023 | Approved | ROY SPAULDING |
| Drywall Nailing | 11/28/2023 | Approved | AMY COLIN |
| ELECTRICAL-Final | 11/28/2023 | Corrections Issued | AMY COLIN |
| Final | 11/28/2023 | Corrections Issued | AMY COLIN |
| Green Building Final | 11/28/2023 | Approved | AMY COLIN |
| HVAC-Final | 11/28/2023 | Approved | AMY COLIN |
| PLUMBING-Final | 11/28/2023 | Corrections Issued | AMY COLIN |
| Service/Power Release | 11/28/2023 | Not Ready for Inspection | AMY COLIN |
| Final | 1/12/2024 | Partial Approval | AMY COLIN |
| SGSOV-Seismic Gas S/O Valve | 1/12/2024 | SGSOV Approved | AMY COLIN |
| Service/Power Release | 1/12/2024 | Approved | AMY COLIN |
| Final | 1/26/2024 | OK to Issue CofO | AMY COLIN |