10649 W CAPELLO WAY 90077
Certificate Information: 10649 W CAPELLO WAY 90077
- Application / Permit
- 16010-10000-00036
- Plan Check / Job No.
- B16LA00211
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (7) Garage - Private
- Work Description
- NEW 2-CAR GARAGE
- Permit Issued
- Issued on 11/8/2017
- Issuing Office
- West Los Angeles
- Current Status
- Issued on 11/8/2017
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 1/7/2016 | APPLICANT |
| Assigned to Plan Check Engineer | 1/14/2016 | TARIK SAOUD |
| Corrections Issued | 1/17/2016 | TARIK SAOUD |
| Quality Review Completed | 1/28/2016 | DOUGLAS NAKATANI |
| Building Plans Picked Up | 2/1/2016 | APPLICANT |
| Green Plans Picked Up | 8/31/2016 | APPLICANT |
| Applicant returned to address corrections | 1/18/2017 | TARIK SAOUD |
| Applicant returned to address corrections | 2/8/2017 | TARIK SAOUD |
| Plan Check Approved | 11/8/2017 | TARIK SAOUD |
| Issued | 11/8/2017 | LADBS |
Permit Application Clearance Information
| Address approval | Cleared | 6/15/2016 | HISASHI KOBAYAKAWA |
| BHO/Hillside ordinance | Cleared | 6/15/2016 | HISASHI KOBAYAKAWA |
| BHO/Hillside ordinance | Cleared | 6/15/2016 | HISASHI KOBAYAKAWA |
| BHO/Hillside ordinance | Cleared | 6/15/2016 | HISASHI KOBAYAKAWA |
| BHO/Hillside ordinance | Cleared | 6/15/2016 | HISASHI KOBAYAKAWA |
| Construction within easement | Cleared | 12/15/2016 | WALTER RAMIREZ |
| BHO/Hillside ordinance | Cleared | 4/6/2017 | ROCHELLE DUNGCA |
| Eng Process Fee Ord 176,300 | Cleared | 4/6/2017 | ROCHELLE DUNGCA |
| Permit | Cleared | 4/6/2017 | ROCHELLE DUNGCA |
| Sewer availability | Cleared | 4/6/2017 | ROCHELLE DUNGCA |
| Work Adjacent to Public Way | Cleared | 4/6/2017 | ROCHELLE DUNGCA |
| Excavation more than 5-ft deep | Cleared | 4/19/2017 | CALOSHA APPROVED |
| Grading Pre-Inspection | Cleared | 4/19/2017 | TARIK SAOUD |
| Low Impact Development | Cleared | 7/3/2017 | RYAN HUDSON |
| Roof/Waste drainage to street | Cleared | 7/3/2017 | CELINA MORENO |
| CPC | Cleared | 9/14/2017 | BRIAN CARR |
| Hydrant and Access approval | Cleared | 9/14/2017 | ROBERT DUFF |
| Green Code | Cleared | 10/6/2017 | SEAN DANG |
| Hold | Cleared | 4/25/2018 | LOURDES RAMIRO |
Contact Information
| Architect | Maly, Farzin; Lic. No.: C33731 | PO BOX 57002 SHERMAN OAKS, CA 91413 |
| Contractor | Owner-Builder | , |
| Engineer | Melkonians, Armen; Lic. No.: C55884 | 435 N BEVERLY DR #208 BEVERLY HILLS, CA 90210 |
| Engineer | Minas, Caro Jolfaie; Lic. No.: GE601 | 4742 SAN FERNANDO RD GLENDALE, CA 91204 |
| Engineer | Pirbadian, Amir; Lic. No.: C72413 | 5435 BALBOA BLVD 212 ENCINO, CA 91436 |
Inspector Information
| RYAN SALAZAR, (310) 914-3862 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Piling/Pier/Caisson | 3/9/2020 | Partial Approval | CHRISTOPHER WILSON |
| Piling/Pier/Caisson | 6/2/2020 | Corrections Issued | CHRISTOPHER WILSON |
| Piling/Pier/Caisson | 6/9/2020 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 6/11/2020 | Partial Approval | MATT KELLERMAN |
| Deputy Reinf. Concrete | 6/17/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Footing/Foundation/Slab | 6/18/2020 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| Excavation/Setback/Form/Re-Bar | 6/22/2020 | Corrections Issued | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 6/23/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Footing/Foundation/Slab | 6/23/2020 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 7/6/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Excavation/Setback/Form/Re-Bar | 7/7/2020 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Shotcrete | 7/13/2020 | Partial Approval | MATT KELLERMAN |
| Deputy Drilled-In Anchors | 7/15/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Deputy Drilled-In Anchors | 7/17/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 7/21/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Deputy Shotcrete | 7/22/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Excavation/Setback/Form/Re-Bar | 7/24/2020 | Corrections Issued | CHRISTOPHER WILSON |
| Excavation/Setback/Form/Re-Bar | 7/27/2020 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Shotcrete | 7/29/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 8/5/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Deck | 8/7/2020 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Reinf. Concrete | 8/11/2020 | Conditional Approval | CHRISTOPHER WILSON |
| Footing/Foundation/Slab | 11/18/2020 | Partial Approval | CHRISTOPHER WILSON |
| Special/Order Compliance | 4/5/2024 | Corrections Issued | CHRISTOPHER WILSON |
| BUILDING-Rough-Frame | 9/23/2024 | Approved | CHRISTOPHER WILSON |
| ELECTRICAL-Rough | 9/23/2024 | Approved | CHRISTOPHER WILSON |
| Green Building Rough | 9/23/2024 | Approved | CHRISTOPHER WILSON |
| Insulation | 9/23/2024 | Approved | CHRISTOPHER WILSON |
| Verify Sprinkler Sign Off | 9/23/2024 | Approved | CHRISTOPHER WILSON |