2154 S WESTWOOD BLVD 90025
Certificate Information: 2154 S WESTWOOD BLVD 90025
- Application / Permit
- 16010-10000-00032
- Plan Check / Job No.
- B16LA00191
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- Commercial
- Primary Use
- (13) Office
- Work Description
- NEW 3-STORY OFFICE BLDG WITH LESS THAN 30% OF RELATED RETAIL USE. ATTACHED CARPORT ON REAR PORTION OF 1ST FLOOR. (6) 2-LEVEL MECHANICAL AUTOMOBILE PARKING LIFTS TO PROVIDE 12 SPACES.
- Permit Issued
- Issued on 11/20/2018
- Issuing Office
- Metro
- Current Status
- CofO Issued on 2/13/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/7/2016 | APPLICANT |
| Assigned to Plan Check Engineer | 2/4/2016 | JESSE JIMENEZ |
| Corrections Issued | 2/23/2016 | CHIU TAM |
| Disabled Access Plans Picked Up | 2/25/2016 | APPLICANT |
| Green Plans Picked Up | 3/14/2016 | APPLICANT |
| Quality Review Completed | 3/16/2016 | JOHN VASQUEZ |
| Building Plans Picked Up | 3/18/2016 | APPLICANT |
| Applicant returned to address corrections | 3/31/2016 | CHIU TAM |
| Applicant returned to address corrections | 11/18/2016 | JESSE JIMENEZ |
| Applicant returned to address corrections | 11/22/2016 | JESSE JIMENEZ |
| Applicant returned to address corrections | 1/25/2017 | JESSE JIMENEZ |
| Applicant returned to address corrections | 2/2/2017 | JESSE JIMENEZ |
| Applicant returned to address corrections | 3/13/2017 | JESSE JIMENEZ |
| Applicant returned to address corrections | 3/28/2017 | JESSE JIMENEZ |
| Applicant returned to address corrections | 4/10/2017 | JESSE JIMENEZ |
| Applicant returned to address corrections | 4/20/2017 | JESSE JIMENEZ |
| Plan Check Approved | 11/27/2017 | JESSE JIMENEZ |
| Issued | 11/20/2018 | LADBS |
| CofO in Progress | 2/2/2024 | DERRICK SPENCER |
| Permit Finaled | 2/13/2024 | DAVID TSAU |
| CofO Issued | 2/13/2024 | DAVID TSAU |
| Permit Finaled | 2/13/2024 | DAVID TSAU |
Permit Application Clearance Information
| Address approval | Cleared | 3/30/2016 | ADRIAN HERNANDEZ |
| Hydrant and Access approval | Cleared | 3/30/2016 | ROBERT DUFF |
| Permit | Cleared | 3/30/2016 | ADRIAN HERNANDEZ |
| Work Adjacent to Public Way | Cleared | 3/30/2016 | DAVID PEREZ |
| Miscellaneous | Cleared | 4/6/2016 | DAVE MYERS |
| ZA Case | Cleared | 4/6/2016 | HERMAN VAN BUREN |
| Supp. Use District POD/CDO/TDO | Cleared | 4/12/2016 | VICTOR VALLEJO |
| ZI | Cleared | 4/12/2016 | VICTOR VALLEJO |
| Construction near power lines | Cleared | 5/20/2016 | STEVE BROWN |
| Construction within easement | Cleared | 5/20/2016 | STEVE BROWN |
| Frnt yard landscape/Water mgmt | Cleared | 6/7/2016 | BRIAN CARR |
| Prkng lot landscape/Water mgmt | Cleared | 6/7/2016 | BRIAN CARR |
| ZI | Cleared | 6/7/2016 | BRIAN CARR |
| DAS Clearance | Cleared | 12/7/2016 | EDDIE GARIN |
| Specific Plan | Cleared | 1/25/2017 | EILEEN HUNT |
| Bicycle Parking | Cleared | 2/2/2017 | JAMES KHO |
| Eng Process Fee Ord 176,300 | Cleared | 2/2/2017 | CARLA VALLADARES |
| Sewer availability | Cleared | 4/11/2017 | RAVIL MANAPOV |
| Green Code | Cleared | 4/14/2017 | JOHN KLARIN |
| Highway dedication | Cleared | 5/12/2017 | ANDREW SLUSSER |
| Driveway location | Cleared | 9/12/2017 | PEDRO AYALA |
| Specific Plan | Cleared | 9/12/2017 | PEDRO AYALA |
| Low Impact Development | Cleared | 11/8/2017 | IDA MEISAMI-FARD |
| Roof/Waste drainage to street | Cleared | 11/8/2017 | RAVIL MANAPOV |
| Building over 3-story or 36-ft | Cleared | 11/27/2017 | CALOSHA APPROVED |
Contact Information
| Architect | Khajavi, Sina; Lic. No.: C19510 | 4040 PALOS VERDES DR N STE 201 ROLLING HILLS ESTATES, CA 90274 |
| Contractor | American First Construction; Lic. No.: 844481-B | 3105 GRANVILLE AVENUE LOS ANGELES, CA 90066 |
| Engineer | Namdar, Mansour Tom; Lic. No.: S2976 | 16867 SEVERO PLACE ENCINO, CA 91436 |
Inspector Information
| DERRICK SPENCER, (310) 914-3919 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 11/26/2018 | Approved | DERRICK SPENCER |
| Pre-Inspection | 11/29/2018 | Not Ready for Inspection | DERRICK SPENCER |
| Pre-Inspection | 12/3/2018 | Approved | DERRICK SPENCER |
| SUSMP-Std. Urban Storm Water | 12/6/2018 | Approved | DERRICK SPENCER |
| Special/Order Compliance | 12/12/2018 | Approved | DERRICK SPENCER |
| Special/Order Compliance | 1/15/2019 | Approved | DERRICK SPENCER |
| Special/Order Compliance | 1/22/2019 | Approved | DERRICK SPENCER |
| Pre-Inspection | 1/25/2019 | Approved | DERRICK SPENCER |
| Special/Order Compliance | 1/25/2019 | Approved | DERRICK SPENCER |
| Footing/Foundation/Slab | 2/20/2019 | Partial Approval | DERRICK SPENCER |
| METHANE-Barrier | 2/20/2019 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Subgrade | 2/20/2019 | Not Ready for Inspection | DERRICK SPENCER |
| Pre-Inspection | 2/21/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 3/20/2019 | Approved | DERRICK SPENCER |
| Deputy Grading | 3/21/2019 | Approved | DERRICK SPENCER |
| Deputy Grading | 3/22/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Concrete | 3/22/2019 | Approved | DERRICK SPENCER |
| Deputy Grading | 3/26/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Concrete | 3/26/2019 | Approved | DERRICK SPENCER |
| Deputy Grading | 3/27/2019 | Approved | DERRICK SPENCER |
| Deputy Drilled-In Anchors | 7/5/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 8/12/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 8/13/2019 | Approved | DERRICK SPENCER |
| Special/Order Compliance | 8/21/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 8/27/2019 | Approved | DERRICK SPENCER |
| METHANE-Barrier | 8/27/2019 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Subgrade | 8/27/2019 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 8/28/2019 | Partial Approval | DERRICK SPENCER |
| Deputy Reinf. Concrete | 8/29/2019 | Approved | DERRICK SPENCER |
| Footing/Foundation/Slab | 9/3/2019 | Partial Approval | DERRICK SPENCER |
| METHANE-Barrier | 9/3/2019 | Approved | DERRICK SPENCER |
| METHANE-Subgrade | 9/3/2019 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 9/20/2019 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Subgrade | 9/20/2019 | Not Ready for Inspection | DERRICK SPENCER |
| Deputy Reinf. Concrete | 9/26/2019 | Approved | DERRICK SPENCER |
| Footing/Foundation/Slab | 9/27/2019 | Partial Approval | DERRICK SPENCER |
| METHANE-Subgrade | 9/27/2019 | Partial Approval | DERRICK SPENCER |
| Deputy Reinf. Concrete | 10/2/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/10/2019 | Approved | DERRICK SPENCER |
| Masonry Wall/Backfill | 10/15/2019 | Partial Approval | TONY HARTONO |
| Deputy Reinf. Masonry | 10/16/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/21/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/22/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/23/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/24/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 10/31/2019 | Approved | DERRICK SPENCER |
| Deputy Reinf. Masonry | 11/1/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 11/26/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 11/27/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 12/2/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 12/3/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 12/4/2019 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 1/2/2020 | Approved | DERRICK SPENCER |
| Deputy Steel/Welding | 1/8/2020 | Approved | DERRICK SPENCER |
| Green Building Rough | 1/31/2020 | Approved | DERRICK SPENCER |
| METHANE-Rough | 1/31/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Structural Steel Frame | 1/31/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Verify Sprinkler Sign Off | 1/31/2020 | Approved | DERRICK SPENCER |
| METHANE-Rough | 4/20/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Wood Frame | 4/20/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Light Gage Steel Frame | 4/21/2020 | Partial Approval | DERRICK SPENCER |
| Drywall Nailing | 4/29/2020 | Partial Approval | DERRICK SPENCER |
| Light Gage Steel Frame | 5/19/2020 | Approved | DERRICK SPENCER |
| METHANE-Rough | 7/29/2020 | Approved | DERRICK SPENCER |
| Wood Frame | 7/29/2020 | Partial Approval | DERRICK SPENCER |
| Interior/Exterior Lathing | 7/31/2020 | Partial Approval | DERRICK SPENCER |
| Pre-Inspection | 9/2/2020 | Approved | DERRICK SPENCER |
| Insulation | 10/23/2020 | Not Ready for Inspection | JOHN DODGE |
| Insulation | 10/26/2020 | Partial Approval | DERRICK SPENCER |
| Interior/Exterior Lathing | 11/9/2020 | Partial Approval | TED RIES |
| Footing/Foundation/Slab | 11/23/2020 | Partial Approval | DERRICK SPENCER |
| METHANE-Subgrade | 11/23/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Floor/Roof Diaphrgm/Shear Wall | 12/1/2020 | Not Ready for Inspection | DERRICK SPENCER |
| Masonry Wall/Backfill | 12/1/2020 | Partial Approval | DERRICK SPENCER |
| Wall Anchors | 12/7/2020 | Partial Approval | DERRICK SPENCER |
| Insulation | 2/8/2021 | Partial Approval | DERRICK SPENCER |
| Special/Order Compliance | 3/8/2021 | Approved | DERRICK SPENCER |
| Structural Steel Frame | 4/20/2021 | Not Ready for Inspection | DERRICK SPENCER |
| Insulation | 4/23/2021 | Approved | DERRICK SPENCER |
| Structural Steel Frame | 4/23/2021 | Approved | DERRICK SPENCER |
| Insulation | 5/12/2021 | Partial Approval | PAUL DAVIDSON |
| Drywall Nailing | 5/19/2021 | Partial Approval | DERRICK SPENCER |
| Drywall Nailing | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| Final | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| Footing/Foundation/Slab | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| Green Building Final | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| METHANE-Subgrade | 5/8/2023 | Approved | NICK LAROCCA |
| Reinforced Masonry Frame | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| SGSOV-Seismic Gas S/O Valve | 5/8/2023 | SGSOV Not Ready | NICK LAROCCA |
| Smoke Detectors | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| Wood Frame | 5/8/2023 | Not Ready for Inspection | NICK LAROCCA |
| Drywall Nailing | 5/17/2023 | Approved | DERRICK SPENCER |
| Final | 5/17/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 5/17/2023 | Approved | DERRICK SPENCER |
| Green Building Final | 5/17/2023 | Approved | DERRICK SPENCER |
| Reinforced Masonry Frame | 5/17/2023 | Approved | DERRICK SPENCER |
| SGSOV-Seismic Gas S/O Valve | 5/17/2023 | SGSOV Approved | DERRICK SPENCER |
| Smoke Detectors | 5/17/2023 | Approved | DERRICK SPENCER |
| Wood Frame | 5/17/2023 | Approved | DERRICK SPENCER |
| Grading Pre-Inspection | 5/19/2023 | Approved | DERRICK SPENCER |
| Final | 11/15/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Final | 11/29/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Final | 1/31/2024 | OK to Issue CofO | DERRICK SPENCER |