23143 W LEONORA DR 91367
Certificate Information: 23143 W LEONORA DR 91367
- Application / Permit
- 15047-20000-00221
- Plan Check / Job No.
- B15VN02137
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 12' X 20' SWIMMING POOL AND 6' X 7' SPA WITH AUTO POOL COVER, PER STD. PLAN #268 AND ENG. DETAIL.
- Permit Issued
- Issued on 2/20/2015
- Issuing Office
- Valley
- Current Status
- CofO in Progress on 1/2/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 2/20/2015 | APPLICANT |
| Assigned to Plan Check Engineer | 2/20/2015 | ARMEN SARKISIAN |
| Plan Check Approved | 2/20/2015 | ARMEN SARKISIAN |
| Issued | 2/20/2015 | LADBS |
| CofO in Progress | 10/10/2024 | TROY SANDERS |
| No Progress | 1/2/2025 | HENRY KIM |
| CofO in Progress | 1/2/2025 | HENRY KIM |
| CofO in Progress | 3/26/2026 | ROBERT GOLD |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 2/20/2015 | LEE GUILBEAUX |
| Sewer availability | Cleared | 2/20/2015 | LEE GUILBEAUX |
Contact Information
| Contractor | Ventura Pools Spas & Waterfeatures; Lic. No.: 950675-C53 | 2510-9 LAS POSAS #166 CAMARILLO, CA 93010 |
| Engineer | Lacher, Todd Lee; Lic. No.: C67656 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Gas Piping or Gas Test | 3/11/2015 | Approved | FRED HANNUM |
| Pre-Gunite | 3/11/2015 | Approved | FRED HANNUM |
| Special/Order Compliance | 3/17/2015 | Approved | FRED HANNUM |
| Deck | 4/9/2015 | Approved | FRED HANNUM |
| Enclosure/Fence | 6/10/2015 | Not Ready for Inspection | FRED HANNUM |
| Enclosure/Fence | 6/18/2015 | Approved | FRED HANNUM |
| Equipment Noise Level | 10/18/2023 | Not Ready for Inspection | ALFREDO FLORES |
| Excavation/Setback/Form/Re-Bar | 10/10/2024 | Approved | TROY SANDERS |
| Final | 10/10/2024 | Conditional Approval | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 10/10/2024 | SGSOV Approved | TROY SANDERS |
| Special/Order Compliance | 1/6/2025 | Corrections Issued | TROY SANDERS |
| Pool Equipment Noise Test | 5/1/2026 | Approved | FELIPE PENICHE |