17349 W SATICOY ST 91325
Certificate Information: 17349 W SATICOY ST 91325
- Application / Permit
- 15014-20000-05071
- Plan Check / Job No.
- B15VN14857
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Recreation Room
- Work Description
- ADD 32' X 33' REC. ROOM WITH STORAGE ROOM AND POOL BATH ATTACHED TO EAST SIDE OF DETACHED GARAGE; ADD ALSO 18'9" X 11' LAUNDRY/STORAGE ROOM ATTACHED TO WEST SIDE OF GARAGE. ALL WITH INDEPENDENT EXTERIOR ACCESS AND ARE PER ENG.
- Permit Issued
- Issued on 11/19/2015
- Issuing Office
- Valley
- Current Status
- CofO Issued on 11/13/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/4/2015 | APPLICANT |
| Assigned to Plan Check Engineer | 11/4/2015 | SIAVOSH POURSABAHIAN |
| Corrections Issued | 11/4/2015 | JEFFREY TANGONAN |
| Plan Check Approved | 11/19/2015 | ALDOUS CHIC |
| Issued | 11/19/2015 | LADBS |
| CofO in Progress | 11/4/2025 | GAREN HAYRAPETYAN |
| CofO Issued | 11/13/2025 | RUBEN SALAS |
| Permit Finaled | 11/13/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 11/19/2015 | RICHARD SOUTHERLAND |
| Low Impact Development | Cleared | 11/19/2015 | MARTIN FRAGOSO |
| Roof/Waste drainage to street | Cleared | 11/19/2015 | RICHARD SOUTHERLAND |
Contact Information
| Engineer | Azizisefat, Solayman; Lic. No.: C57840 | 19510 VENTURA BLVD STE 110 TARZANA, CA 91356 |
Inspector Information
| MICHAEL CORTEZ, (818) 374-1176 | Office Hours: 7:00-8:00 AM MON-FRI |
| WILLIAM WREN, (818) 374-1176 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/1/2015 | Approved | JOHN COLEMAN |
| Underground Mechanical | 12/1/2015 | Approved | JOHN COLEMAN |
| Excavation/Setback/Form/Re-Bar | 12/3/2015 | Approved | JOHN COLEMAN |
| Underground Mechanical | 12/15/2015 | Not Ready for Inspection | JACK KARGODORIAN |
| Underground Mechanical | 12/16/2015 | Approved | JACK KARGODORIAN |
| BUILDING-Rough-Frame | 12/21/2015 | Not Ready for Inspection | JOHN KIDWELL |
| Green Building Rough | 12/21/2015 | Not Ready for Inspection | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 12/22/2015 | Not Ready for Inspection | JACK KARGODORIAN |
| Floor/Roof Diaphrgm/Shear Wall | 12/23/2015 | Partial Approval | JACK KARGODORIAN |
| Interior/Exterior Lathing | 12/31/2015 | Approved | JOHN COLEMAN |
| HVAC-Rough | 1/4/2016 | Not Ready for Inspection | JACK KARGODORIAN |
| ELECTRICAL-Rough | 1/6/2016 | Approved | JACK KARGODORIAN |
| HVAC-Rough | 1/6/2016 | Approved | JACK KARGODORIAN |
| PLUMBING-Rough | 1/6/2016 | Approved | JACK KARGODORIAN |
| Insulation | 1/7/2016 | Approved | JOHN COLEMAN |
| BUILDING-Rough-Frame | 1/12/2016 | Approved | JACK KARGODORIAN |
| Drywall Nailing | 1/12/2016 | Approved | JACK KARGODORIAN |
| Green Building Rough | 1/12/2016 | Approved | JACK KARGODORIAN |
| Final | 1/28/2016 | Not Ready for Inspection | JOHN COLEMAN |
| Green Building Final | 1/28/2016 | Approved | JOHN COLEMAN |
| SGSOV-Seismic Gas S/O Valve | 1/28/2016 | SGSOV Approved | JOHN COLEMAN |
| Smoke Detectors | 1/28/2016 | Approved | JOHN COLEMAN |
| Final | 2/1/2016 | Not Ready for Inspection | JACK KARGODORIAN |
| ELECTRICAL-Final | 2/2/2016 | Approved | JACK KARGODORIAN |
| Final | 10/20/2025 | Corrections Issued | OGANES TARAKHCHYAN |
| Final | 10/23/2025 | Not Ready for Inspection | GAREN HAYRAPETYAN |
| Final | 11/4/2025 | OK to Issue CofO | GAREN HAYRAPETYAN |