1740 N CORREA WAY 90049
Certificate Information: 1740 N CORREA WAY 90049
- Application / Permit
- 15010-20000-01050
- Plan Check / Job No.
- B15VN03322
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- (N) Two-Story Irr. Shape Fully Sprinklered Single Family Dwelling with attached Two-Car Garage, Basement, and rooftop deck.
- Permit Issued
- Issued on 6/12/2020
- Issuing Office
- Valley
- Current Status
- Issued on 6/12/2020
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 3/18/2015 | APPLICANT |
| Green Plans Picked Up | 4/2/2015 | APPLICANT |
| Assigned to Plan Check Engineer | 4/9/2015 | OMID HEDAYAT |
| Corrections Issued | 4/20/2015 | OMID HEDAYAT |
| Quality Review Completed | 4/21/2015 | STEVEN KIM |
| Building Plans Picked Up | 4/21/2015 | APPLICANT |
| Applicant returned to address corrections | 5/19/2015 | OMID HEDAYAT |
| Applicant returned to address corrections | 7/10/2015 | OMID HEDAYAT |
| Applicant returned to address corrections | 12/15/2017 | OMID HEDAYAT |
| Applicant returned to address corrections | 1/5/2018 | OMID HEDAYAT |
| Applicant returned to address corrections | 3/7/2018 | OMID HEDAYAT |
| Applicant returned to address corrections | 3/22/2018 | OMID HEDAYAT |
| Applicant returned to address corrections | 2/11/2020 | OMID HEDAYAT |
| Plan Check Approved | 5/7/2020 | OMID HEDAYAT |
| Issued | 6/12/2020 | LADBS |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 9/1/2015 | RICHARD SOUTHERLAND |
| BHO/Hillside ordinance | Cleared | 9/1/2015 | RICHARD SOUTHERLAND |
| Eng Process Fee Ord 176,300 | Cleared | 9/4/2015 | JOHN LIN |
| Sewer availability | Cleared | 9/4/2015 | JOHN LIN |
| Hydrant and Access approval | Cleared | 9/8/2015 | JOHN DALLAS |
| BHO/Hillside ordinance | Cleared | 9/24/2015 | DAVID ARCHER |
| BHO/Hillside ordinance | Cleared | 10/30/2015 | DAVID ARCHER |
| Highway dedication | Cleared | 10/30/2015 | DAVID ARCHER |
| Address approval | Cleared | 7/1/2016 | HOWARD COOPER |
| GPI Written Notices | Cleared | 12/15/2017 | ABDUL CHEGENI |
| Grading Pre-Inspection | Cleared | 12/15/2017 | ABDUL CHEGENI |
| Miscellaneous | Cleared | 3/15/2018 | DAISY BENICIA |
| Miscellaneous | Cleared | 8/16/2018 | HISASHI KOBAYAKAWA |
| Low Impact Development | Cleared | 8/23/2019 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 8/23/2019 | JEANETTE VONG |
| Construction near power lines | Cleared | 8/27/2019 | WALTER RAMIREZ |
| Green Code | Cleared | 9/4/2019 | MICHAEL AYERS |
| Miscellaneous | Cleared | 4/22/2020 | NIKTA MOUSAVI |
Contact Information
| Architect | Stockton,, Kenneth; Lic. No.: C19870 | 26500 W AGOURA RD. PMB # 844 CALABASAS, CA 91302 |
| Contractor | Owner-Builder | , |
| Engineer | Richard, Freitas; Lic. No.: C49072 | 595 W LAMBERT RD 104 BREA, CA 92821 |
Inspector Information
| KEVIN SARGSYAN, (310) 914-3889 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Grading Pre-Inspection | 8/24/2020 | Partial Inspection | MATTHEW JENKINS |
| Underground Mechanical | 1/12/2021 | Partial Approval | JOHNNY MIRANDA |
| Excavation/Setback/Form/Re-Bar | 2/17/2021 | Partial Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 2/17/2021 | Partial Approval | JUAN VALENZUELA |
| Deputy Reinf. Concrete | 2/23/2021 | Conditional Approval | JUAN VALENZUELA |
| Deputy Shotcrete | 3/18/2021 | Approved | ROBERT SHELLY |
| Deputy Shotcrete | 6/3/2021 | Partial Approval | PIERRE VEGA |
| Excavation/Setback/Form/Re-Bar | 6/3/2021 | Corrections Issued | PIERRE VEGA |
| Excavation/Setback/Form/Re-Bar | 6/8/2021 | Partial Approval | JUAN VALENZUELA |
| Deputy Shotcrete | 6/9/2021 | Conditional Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 11/1/2021 | Partial Approval | ANDREW NAVE |
| Pre-Inspection | 5/4/2023 | Partial Inspection | KEVIN SARGSYAN |
| Footing/Foundation/Slab | 9/22/2023 | Corrections Issued | KEVIN SARGSYAN |
| Footing/Foundation/Slab | 9/26/2023 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 10/20/2023 | Corrections Issued | KEVIN SARGSYAN |
| Structural Steel Frame | 4/18/2024 | Partial Inspection | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 5/16/2024 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/9/2024 | Corrections Issued | KEVIN SARGSYAN |
| Deputy Wood Construction | 7/11/2024 | Conditional Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/17/2024 | Corrections Issued | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/22/2024 | Partial Approval | KEVIN SARGSYAN |
| PLUMBING-Rough | 1/6/2025 | Not Ready for Inspection | KEVIN SARGSYAN |
| PLUMBING-Rough | 1/27/2025 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Rough | 2/19/2025 | Approved | EVAN COOPER |
| HVAC-Rough | 2/28/2025 | Corrections Issued | KEVIN SARGSYAN |
| Deputy Steel/Welding | 3/7/2025 | Conditional Approval | KEVIN SARGSYAN |
| Shower Pan | 3/7/2025 | Approved | KEVIN SARGSYAN |
| HVAC-Rough | 6/3/2025 | Corrections Issued | HERBERT GIRON |
| HVAC-Rough | 6/10/2025 | Approved | KEVIN SARGSYAN |
| Sewer | 6/10/2025 | Corrections Issued | KEVIN SARGSYAN |
| Sewer | 6/12/2025 | Not Ready for Inspection | KEVIN SARGSYAN |
| Special/Order Compliance | 6/12/2025 | Corrections Issued | KEVIN SARGSYAN |
| Sewer | 6/17/2025 | Approved | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 7/3/2025 | Corrections Issued | ARAM AVEDISIAN |
| Insulation | 7/3/2025 | Partial Approval | ARAM AVEDISIAN |
| ELECTRICAL-Rough | 8/28/2025 | Corrections Issued | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 10/10/2025 | Partial Approval | MEL KHACHATOURIAN |
| ELECTRICAL-Rough | 12/19/2025 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 1/7/2026 | Corrections Issued | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 4/8/2026 | Partial Approval | KEVIN SARGSYAN |