1515 N SAN FERNANDO ROAD 1-87 90031

Certificate Information: 1515 N SAN FERNANDO ROAD 1-87 90031

Application / Permit
12010-10000-01922
Plan Check / Job No.
B12LA10065
Group
Building
Type
Bldg-New
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Construct 87-unit apartment building (86 restricted affordable residential units for households earning up to a max 60% AMI plus one non-restricted manager unit) over 1-level basement parking.
Permit Issued
Issued on 1/24/2013
Issuing Office
Metro
Current Status
CofO Issued on 5/18/2015
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/20/2012 APPLICANT
Assigned to Plan Check Engineer 9/27/2012 TIEN JEN WANG
Corrections Issued 10/5/2012 TIEN JEN WANG
Quality Review Completed 10/9/2012 CHARLES CHANG
Building Plans Picked Up 10/11/2012 APPLICANT
Disabled Access Plans Picked Up 10/11/2012 APPLICANT
Green Plans Picked Up 10/15/2012 APPLICANT
Applicant returned to address corrections 11/5/2012 TIEN JEN WANG
Applicant returned to address corrections 11/13/2012 TIEN JEN WANG
Plan Check Approved 1/24/2013 TIEN JEN WANG
Issued 1/24/2013 LADBS
TCO Issued (Expire Date: 03-29-2015) 9/30/2014 HAMID PISHEHVAR
TCO Issued (Expire Date: 09-25-2015) 3/29/2015 HAMID PISHEHVAR
CofO in Progress 5/18/2015 WILLIAM GARCIA
CofO Issued 5/18/2015 RICKEY JACKSON
Permit Finaled 5/18/2015 RICKEY JACKSON

Permit Application Clearance Information

Address approval Cleared 11/6/2012 PAMELA TENEZA
Highway dedication Cleared 11/6/2012 ARMENIA HERNANDEZ
Permit Cleared 11/6/2012 ARMENIA AGUILAR
Hydrant and Access approval Cleared 11/9/2012 JOHN DALLAS
Title 19 building approval Cleared 11/9/2012 DAVE MYERS
Eng Process Fee Ord 176,300 Cleared 11/28/2012 ARMENIA HERNANDEZ
Driveway location Cleared 12/4/2012 COLLINS ALLAN
DAS Clearance Cleared 12/11/2012 WAI LAU
Green Code Cleared 12/11/2012 MARTHA DIAZ
Building over 3-story or 36-ft Cleared 12/13/2012 CALOSHA APPROVED
Excavation more than 5-ft deep Cleared 12/13/2012 CALOSHA APPROVED
Drainage to Storm Drain Cleared 1/10/2013 ARMENIA HERNANDEZ
Low Impact Development Cleared 1/10/2013 AMMAR ELTAWIL
Roof/Waste drainage to street Cleared 1/10/2013 ARMENIA HERNANDEZ
Sewer availability Cleared 1/10/2013 ARMENIA HERNANDEZ
Stormwater Pollution Mitigatn Cleared 1/10/2013 AMMAR ELTAWIL
"Q" conditions Cleared 1/18/2013 BRIDGETTE WOOTEN
CPC Cleared 1/18/2013 BRIDGETTE WOOTEN
CPC Cleared 1/18/2013 BRIDGETTE WOOTEN
Frnt yard landscape/Water mgmt Cleared 1/18/2013 BRIDGETTE WOOTEN
Opn space landscape/Water mgmt Cleared 1/18/2013 BRIDGETTE WOOTEN
Site Plan review Cleared 1/18/2013 BRIDGETTE WOOTEN
Supp. Use District POD/CDO/TDO Cleared 1/18/2013 BRIDGETTE WOOTEN
Tract Map conditions Cleared 1/18/2013 BRIDGETTE WOOTEN
ZA Case Cleared 1/18/2013 BRIDGETTE WOOTEN
ZA Case Cleared 1/18/2013 BRIDGETTE WOOTEN
Housing density bonus Cleared 1/24/2013 MARITES CUNANAN

Contact Information

Architect Empakeris, Donatas Eduard; Lic. No.: C13779 1535 6TH STREET SUITE 101   DE ARCHITECTS    SANTA MONICA, CA 90401
Contractor A P West Coast Inc; Lic. No.: 914709-B 6701 WEST 23 STREET      MINNEAPOLIS, MN 55426
Engineer Berliner, Neal David; Lic. No.: GE2576 4913 MONUMENT ST      SIMI VALLEY, CA 93063
Engineer Labib, Youhanna T; Lic. No.: S4549 900 WILSHIRE BLVD STE 936      LOS ANGELES, CA 90017
Engineer Waber, Mahir Marwan; Lic. No.: C69050 2120 E HILL ST 307      SIGNAL HILL, CA 90756

Inspector Information

LARRY ARNICK, (213) 482-0307 Office Hours: 7:00-8:00 AM MON-FRI
ERNESTO CORRAL, (213) 482-0307 Office Hours: 7:00-8:00 AM MON-FRI
JEFFREY FULTON, (213) 482-0307 Office Hours: 7:00-8:00 AM MON-FRI
RAFAEL ESPINOZA, (213) 482-0307 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Reinf. Concrete 5/31/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 5/31/2013 Partial Inspection WILLIAM GARCIA
SWPPP-Const. Storm Water 5/31/2013 Not Required WILLIAM GARCIA
Deputy Reinf. Concrete 6/6/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/6/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 6/6/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 6/7/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/7/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/10/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/11/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 6/11/2013 Partial Inspection WILLIAM GARCIA
Wood Frame 6/11/2013 Not Ready for Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/12/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/13/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/14/2013 Partial Approval WILLIAM GARCIA
Wood Frame 6/14/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/17/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/18/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/19/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/20/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 6/20/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/21/2013 Partial Approval WILLIAM GARCIA
Wood Frame 6/21/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/24/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 6/24/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/25/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/26/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 6/26/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 6/27/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 6/28/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 7/1/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 7/2/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 7/3/2013 Approved SAKO AGHAZARIAN
Deputy Reinf. Masonry 7/5/2013 Partial Approval JAMES POWERS
Deputy Reinf. Concrete 7/23/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 7/23/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 7/25/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 8/6/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 8/7/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 8/8/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 8/9/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 8/9/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 9/17/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 9/26/2013 Partial Approval LESLIE TRUJILLO
Footing/Foundation/Slab 9/26/2013 Partial Approval LESLIE TRUJILLO
Deputy Reinf. Concrete 9/27/2013 Partial Approval LESLIE TRUJILLO
Deputy Reinf. Concrete 9/30/2013 Approved SAKO AGHAZARIAN
Deputy Reinf. Concrete 10/1/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 10/2/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 10/3/2013 Partial Approval WILLIAM GARCIA
Excavation/Setback/Form/Re-Bar 10/3/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 10/4/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 10/7/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 10/17/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 10/18/2013 Partial Approval WILLIAM GARCIA
Deputy Reinf. Concrete 10/21/2013 Partial Approval WILLIAM GARCIA
Footing/Foundation/Slab 10/21/2013 Not Ready for Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 10/22/2013 Partial Approval WILLIAM GARCIA
Green Building Rough 10/22/2013 Not Ready for Inspection MICHAEL TUCK
Wood Frame 10/22/2013 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 10/23/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 10/25/2013 Partial Approval WILLIAM GARCIA
Light Gage Steel Frame 10/25/2013 Partial Inspection WILLIAM GARCIA
Excavation/Setback/Form/Re-Bar 10/28/2013 Partial Inspection WILLIAM GARCIA
Light Gage Steel Frame 10/28/2013 Not Ready for Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 10/29/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 10/30/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 10/31/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 11/1/2013 Conditional Approval WILLIAM THOMPSON
Green Building Rough 11/5/2013 Partial Inspection MICHAEL TUCK
Wood Frame 11/5/2013 Partial Inspection WILLIAM THOMPSON
Deputy Wood Construction 11/6/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 11/7/2013 Partial Approval WILLIAM GARCIA
Insulation 11/7/2013 Partial Inspection WILLIAM GARCIA
Deputy Wood Construction 11/8/2013 Approved SAKO AGHAZARIAN
Deputy Wood Construction 11/12/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 11/15/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 11/19/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 11/27/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 12/4/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 12/5/2013 Partial Approval WILLIAM GARCIA
Wood Frame 12/9/2013 Partial Inspection WILLIAM GARCIA
Deputy Wood Construction 12/16/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 12/17/2013 Partial Approval WILLIAM GARCIA
Deputy Wood Construction 12/19/2013 Partial Approval WILLIAM GARCIA
Green Building Rough 12/20/2013 Not Ready for Inspection MICHAEL TUCK
Wood Frame 12/20/2013 Partial Approval MICHAEL KUHN
Green Building Rough 1/7/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 1/7/2014 Partial Inspection WILLIAM GARCIA
Green Building Rough 1/21/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 1/21/2014 Partial Inspection WILLIAM GARCIA
Green Building Rough 1/23/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 1/23/2014 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Concrete 1/30/2014 Partial Approval WILLIAM GARCIA
Green Building Rough 1/30/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 1/30/2014 Partial Inspection WILLIAM GARCIA
Deputy Wood Construction 1/31/2014 Partial Approval ERNESTO CORRAL
Interior/Exterior Lathing 2/6/2014 Partial Inspection WILLIAM GARCIA
Interior/Exterior Lathing 2/7/2014 Partial Inspection WILLIAM GARCIA
Deputy Wood Construction 2/11/2014 Partial Approval WILLIAM GARCIA
Green Building Rough 2/11/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 2/11/2014 Partial Inspection WILLIAM GARCIA
Green Building Rough 2/12/2014 Partial Approval MICHAEL TUCK
Interior/Exterior Lathing 2/12/2014 Partial Inspection WILLIAM GARCIA
Insulation 2/13/2014 Partial Inspection WILLIAM GARCIA
Drywall Nailing 2/24/2014 Partial Inspection WILLIAM GARCIA
Interior/Exterior Lathing 2/24/2014 Partial Inspection WILLIAM GARCIA
Interior/Exterior Lathing 2/25/2014 Partial Inspection WILLIAM GARCIA
Green Building Rough 3/11/2014 Partial Approval MICHAEL TUCK
Interior/Exterior Lathing 3/11/2014 Partial Inspection ERNESTO CORRAL
Drywall Nailing 3/21/2014 Partial Inspection WILLIAM GARCIA
Drywall Nailing 4/4/2014 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 4/21/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/22/2014 Partial Approval WILLIAM GARCIA
Green Building Rough 4/22/2014 Partial Approval RUSSELL KELLY
Wood Frame 4/22/2014 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 4/23/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/24/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/25/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/28/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/29/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 4/30/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/1/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/2/2014 Approved WILLIAM THOMPSON
Green Building Rough 5/2/2014 Not Ready for Inspection MICHAEL TUCK
Wood Frame 5/2/2014 Partial Approval WILLIAM THOMPSON
Deputy Drilled-In Anchors 5/5/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/5/2014 Partial Approval WILLIAM GARCIA
Light Gage Steel Frame 5/5/2014 Not Ready for Inspection WILLIAM GARCIA
Deputy Drilled-In Anchors 5/6/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/6/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/7/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/8/2014 Partial Approval WILLIAM GARCIA
Floor/Roof Diaphrgm/Shear Wall 5/8/2014 Partial Inspection WILLIAM GARCIA
Deputy Reinf. Masonry 5/9/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/12/2014 Partial Approval WILLIAM GARCIA
Deputy Reinf. Masonry 5/13/2014 Conditional Approval MICHAEL ALVAREZ
Deputy Reinf. Masonry 5/14/2014 Conditional Approval WILLIAM THOMPSON
Deputy Reinf. Masonry 5/15/2014 Approved SAKO AGHAZARIAN
Green Building Rough 5/15/2014 Approved MICHAEL TUCK
Wood Frame 5/15/2014 Partial Approval SAKO AGHAZARIAN
Deputy Drilled-In Anchors 5/20/2014 Partial Approval ERNESTO CORRAL
Wood Frame 6/20/2014 Approved WILLIAM GARCIA
Light Gage Steel Frame 6/26/2014 Partial Inspection ERNESTO CORRAL
Final 9/15/2014 Not Ready for Inspection WILLIAM GARCIA
Footing/Foundation/Slab 9/15/2014 Approved WILLIAM GARCIA
SGSOV-Seismic Gas S/O Valve 9/15/2014 SGSOV Approved WILLIAM GARCIA
Smoke Detectors 9/15/2014 Approved WILLIAM GARCIA
Final 9/17/2014 Not Ready for Inspection WILLIAM GARCIA
Green Building Final 9/17/2014 Partial Inspection MEL KHACHATOURIAN
Final 9/18/2014 Conditional Approval WILLIAM GARCIA
Final 9/29/2014 Partial Inspection ERNESTO CORRAL
Green Building Final 9/29/2014 Conditional Approval RICHARD DOCKUS
Final 9/30/2014 Conditional Approval WILLIAM GARCIA
Green Building Final 10/15/2014 Partial Approval RICHARD DOCKUS
Green Building Final 11/6/2014 Not Ready for Inspection RICHARD DOCKUS
Green Building Final 11/19/2014 Approved DONALD CRICHLOW
Special/Order Compliance 3/3/2015 Not Ready for Inspection WILLIAM GARCIA
Final 5/13/2015 Conditional Approval WILLIAM GARCIA